provided equipment |
USB cable
|
|
---|---|---|
product web sub-family |
Cloud-enabled monitoring
|
|
performance multiplier |
1
|
|
Number of tare power |
54 W
|
|
Number of power module free slots |
0
|
|
Number of power module filled slots |
0
|
|
redundant |
No
|
|
size UPS version |
Internetworking
Server Telecom |
|
UPS size |
S
|
|
value multiplier |
1
|
number of rack unit |
0U
|
|
---|---|---|
color |
Black
|
|
depth |
54.4 cm
|
|
height |
43.5 cm
|
|
mounting location |
Front
|
|
mounting preference |
No preference
|
|
net weight |
50.2 kg
|
|
mounting mode |
Not rack-mountable
|
|
two post mountable |
0
|
|
USB compatible |
Yes
|
|
width |
19.7 cm
|
network frequency |
50/60 Hz +/- 3 Hz auto-sensing
|
|
---|---|---|
plug standard |
IEC 320 C20
Schuko CEE 7 / EU1-16P BS1363A British |
|
input voltage limits |
151…302 V adjustable
160…286 V |
|
inputvolt_other |
220 V
240 V |
|
number of cables |
1
|
|
input voltage |
230 V
|
rated power in W |
1980 W
|
|
---|---|---|
Maximum configurable power in W |
1980 W
|
|
harmonic distortion |
Less than 5 %
|
|
output frequency |
50/60 Hz +/- 3 Hz sync to mains
|
|
outputvolt_other |
220 V
240 V |
|
UPS type |
Line-interactive
|
|
Wave type |
Sine wave
|
|
nb of power socket outlets |
8 IEC 320 C13
2 IEC Jumpers 1 IEC 320 C19 |
|
curve equation |
Efficiency
|
|
curve fixed loss |
0.0039
|
|
curve load maximum |
100 %
|
|
curve load minimum |
1 %
|
|
curve proportional loss |
0
|
|
curve square loss |
0.0056
|
|
curve X-axis maximum |
100 %
|
|
curve test cond ID |
Curve fit of data measured in accordance with the ENERGY STAR Test Method for Uninterruptible Power Supplies. All measurements are taken in normal mode(s), at typical environmental conditions, with 230V/50Hz electrical input and balanced resistive load (PF = 1.0) output.
|
|
curve X-axis minimum |
0 %
|
|
curve X-axis title |
Load
|
|
curve X-axis units |
Percentage
|
|
curve Y-axis maximum |
100 %
|
|
curve Y-axis minimum |
50 %
|
|
curve Y-axis title |
Efficiency
|
|
curve Y-axis units |
Percentage
|
|
graph display |
1
|
|
output voltage |
230 V
|
|
Maximum configurable power in VA |
2200 VA
|
|
rated power in VA |
2200 VA
|
|
Transfer time |
6 ms typical: 10 ms maximum
|
product certifications |
CE
EAC RCM VDE |
|
---|---|---|
standards |
EN/IEC 62040-1
EN/IEC 62040-2 |
ambient air temperature for operation |
0…40 °C
|
|
---|---|---|
relative humidity |
0…95 %
|
|
operating altitude |
0…10000 ft
|
|
ambient air temperature for storage |
-15…45 °C
|
|
Storage Relative Humidity |
0…95 %
|
|
storage altitude |
0.00…15240.00 m
|
|
acoustic level |
45 dBA
|
|
heat dissipation |
275 Btu/h
|
|
show note OP temperature |
No
|
battery type |
Lead-acid battery
|
|
---|---|---|
number of battery filled slots |
0
|
|
number of battery-free slots |
0
|
|
Battery recharge time |
3 h
|
|
number of battery replacement quantity |
1
|
|
additional information |
Configurable for 220: 230 or 240 nominal output voltage
|
|
liquid value |
0
|
|
battery curve |
B
|
|
battery charger power |
260 W rated
|
|
Battery power in VAH |
783 VAh runtime
|
|
battery life |
3…5 year(s)
|
|
extended runtime |
0
|
free slots |
1
|
|
---|---|---|
control panel |
Multifunction LCD status and control console
|
|
alarm |
Alarm when on battery: distinctive low battery alarm: configurable delays
|
|
Emergency power off |
Yes
|
Surge energy rate |
365 J
|
|
---|---|---|
noise suppression |
Full time multi-pole noise filtering : 0.3% IEEE surge let-through : zero clamping response time : meets UL 1449
|
Package 1 Weight |
61.9 kg
|
|
---|---|---|
Package 1 Height |
69.9 cm
|
|
Package 1 width |
38.1 cm
|
|
Package 1 Length |
76.2 cm
|
|
Number of Units in Package 3 |
9
|