Sale!

LP1K0910BD TeSys K contactor – 3P – AC-3 <= 440 V 9 A - 1 NO aux. - 24 V DC coil

Original price was: ₦24,205.00.Current price is: ₦21,405.68. 7.5% VAT

TeSys K contactor – 3P – AC-3 <= 440 V 9 A – 1 NO aux. – 24 V DC coil

SKU: LP1K0910BD Category:
Main
range of product
TeSys K
range
TeSys
product or component type
Contactor
device short name
LP1K
contactor application
Motor control
Resistive load
utilisation category
AC-3
AC-1
AC-4
poles description
3P
pole contact composition
3 NO
[Ie] rated operational current
20 A (at <50 °C) at <= 440 V AC AC-1 for power circuit
9 A at <= 440 V AC AC-3 for power circuit
16 A (at <70 °C) at 690 V AC AC-1 for power circuit
auxiliary contact composition
1 NO
Complementary
auxiliary contacts type
type instantaneous 1 NO
control circuit voltage limits
Operational: 0.8…1.15 Uc (at <50 °C)
Drop-out: 0.1…0.75 Uc (at <50 °C)
[Ui] rated insulation voltage
Power circuit: 600 V conforming to UL 508
Power circuit: 690 V conforming to IEC 60947-4-1
Signalling circuit: 690 V conforming to IEC 60947-4-1
Signalling circuit: 690 V conforming to IEC 60947-5-1
Signalling circuit: 600 V conforming to UL 508
Power circuit: 600 V conforming to CSA C22.2 No 14
Signalling circuit: 600 V conforming to CSA C22.2 No 14
[Uimp] rated impulse withstand voltage
8 kV
overvoltage category
III
mounting support
Rail
Plate
flame retardance
V1 conforming to UL 94
Requirement 2 conforming to NF F 16-101
Requirement 2 conforming to NF F 16-102
tightening torque
1.3 N.m – on screw clamp terminals – with screwdriver Philips No 2
1.3 N.m – on screw clamp terminals – with screwdriver flat Ø 6 mm
[Ue] rated operational voltage
Power circuit: 690 V AC 50/60 Hz
Signalling circuit: <= 690 V AC 50/60 Hz
[Ith] conventional free air thermal current
20 A (at 50 °C) for power circuit
10 A (at 50 °C) for signalling circuit
Irms rated making capacity
110 A AC for power circuit conforming to NF C 63-110
110 A AC for power circuit conforming to IEC 60947
110 A AC for signalling circuit conforming to IEC 60947
rated breaking capacity
110 A at 415 V conforming to IEC 60947
110 A at 440 V conforming to IEC 60947
80 A at 500 V conforming to IEC 60947
110 A at 220…230 V conforming to IEC 60947
110 A at 380…400 V conforming to IEC 60947
70 A at 660…690 V conforming to IEC 60947
associated fuse rating
25 A gG at <= 440 V for power circuit
25 A aM for power circuit
10 A gG for signalling circuit conforming to IEC 60947
10 A gG for signalling circuit conforming to VDE 0660
average impedance
3 mOhm – Ith 20 A 50 Hz for power circuit
inrush power in W
3 W (at 20 °C)
hold-in power consumption in W
3 W at 20 °C
operating time
30…40 ms coil energisation and NO closing
10 ms coil de-energisation and NO opening
safety reliability level
B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
mechanical durability
10 Mcycles
maximum operating rate
3600 cyc/h
minimum switching current
5 mA for signalling circuit
minimum switching voltage
17 V for signalling circuit
insulation resistance
> 10 MOhm for signalling circuit
height
58 mm
width
45 mm
depth
57 mm
net weight
0.225 kg

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.