General Information
-
- Extended Product Type:
- TA200DU-90
-
- Product ID:
- 1SAZ421201R1001
-
- EAN:
- 4013614285868
-
- Catalog Description:
- TA200DU-90 Thermal Overload Relay
-
- Long Description:
- The TA200DU-90 thermal overload relay is an economic electromechanical protection device for the main circuit. It offers reliable and fast protection for motors in the event of overload or phase failure. The device has trip class 10A. Further features are the temperature compensation, trip contact (NC), signal contact (NO), automatic- or manual reset selectable, trip-free mechanism, STOP- and Test function and a trip indication. The overload relays are connected directly to the block contactors. Single mounting kits are available as accessory.
Categories
- Products » Low Voltage Products and Systems » Control Products » Contactors » Thermal Overload Relays
Technical
-
- Setting Range:
- 66 … 90 A
-
- Rated Operational Voltage:
- Auxiliary Circuit 440 V DC
Auxiliary Circuit 500 V AC
Main Circuit 690 V AC
-
- Rated Operational Current (Ie):
- 90 A
-
- Rated Operational Current AC-3 (Ie):
- 90 A
-
- Rated Frequency (f):
- Auxiliary Circuit 50 Hz
Auxiliary Circuit 60 Hz
Auxiliary Circuit DC
Main Circuit 60 Hz
Main Circuit 50 Hz
Main Circuit DC
-
- Rated Impulse Withstand Voltage (Uimp):
- Auxiliary Circuit 6 kV
Main Circuit 6 kV
-
- Rated Insulation Voltage (Ui):
- 690 V
-
- Number of Poles:
- 3
-
- Number of Auxiliary Contacts NC:
- 1
-
- Number of Auxiliary Contacts NO:
- 1
-
- Number of Protected Poles:
- 3
-
- Conventional Free-air Thermal Current (Ith):
- Auxiliary Circuit NC 5 A
Auxiliary Circuit NO 5 A
-
- Rated Operational Current AC-15 (Ie):
- (120 V) NC 3 A
(120 V) NO 1.5 A
(240 V) NC 3 A
(240 V) NO 1.5 A
(400 V) NC 1.9 A
(400 V) NO 1 A
(440 V) NC 1 A
(440 V) NO 1 A
(500 V) NC 1 A
(500 V) NO 1 A
-
- Rated Operational Current DC-13 (Ie):
- (125 V) NC 0.25 A
(125 V) NO 0.25 A
(24 V) NC 1.25 A
(24 V) NO 1.25 A
(250 V) NC 0.12 A
(250 V) NO 0.04 A
(60 V) NC 0.25 A
(60 V) NO 0.25 A
-
- Degree of Protection:
- Housing IP20
Main Circuit Terminals IP00
-
- Pollution Degree:
- 3
-
- Connecting Capacity Auxiliary Circuit:
- Flexible with Ferrule 1/2x 0.75 … 2.5 mm²
Flexible 1/2x 0.75 … 2.5 mm²
Rigid 1/2x 0.75 … 4 mm²
-
- Connecting Capacity Main Circuit:
- Hole Diameter > 10 mm²
Rigid or Flexible with Cable Lug 1x 25 … 120 mm²
-
- Tightening Torque:
- Auxiliary Circuit 1 … 1.3 N·m
Main Circuit 25 N·m
-
- Wire Stripping Length:
- Auxiliary Circuit 9 mm
-
- Recommended Screw Driver:
- Auxiliary Circuit Pozidriv 1
Main Circuit Open Bars
-
- Mounting Position:
- Position 1 to 6
-
- Power Loss:
- at Rated Operating Conditions per Pole 2.4 … 4.5 W
-
- Suitable For:
- A145
A185
AF145
AF185
AF190
AF205
-
- Standards:
- IEC/EN 60947-1
IEC/EN 60947-4-1
IEC/EN 60947-5-1
UL 60947-1
UL 60947-4-1
Technical UL/CSA
-
- Maximum Operating Voltage UL/CSA:
- Main Circuit 600 V AC
-
- Ampere Rating UL/CSA:
- 90 A
-
- Contact Rating UL/CSA:
- (NC:) B600
(NO:) C600
-
- Connecting Capacity Main Circuit UL/CSA:
- Flexible 1x 4-0000 AWG
Stranded 1x 4-0000 AWG
-
- Connecting Capacity Auxiliary Circuit UL/CSA:
- Flexible 1/2x 18-14 AWG
Stranded 1/2x 18-14 AWG
-
- Tightening Torque UL/CSA:
- Auxiliary Circuit 12 in·lb
Main Circuit 220 in·lb