General Information
-
- Extended Product Type:
- AF12-30-10-13
-
- Product ID:
- 1SBL157001R1310
-
- EAN:
- 3471523110335
-
- Catalog Description:
- AF12-30-10-13 100-250V50/60HZ-DC Contactor
-
- Long Description:
- AF12 contactors are used for controlling power circuits up to 690 V AC and 220 V DC. They are mainly used for controlling 3-phase motors, non-inductive or slightly inductive loads. AF… contactors include an electronic coil interface accepting a wide control voltage Uc min. … Uc max. Only four coils cover control voltages between 24…500 V 50/60 Hz or 20…500 V DC. AF contactors can manage large control voltage variations. One coil can be used for different control voltages used worldwide without any coil change. AF contactors have built-in surge protection and do not require additional surge suppressors. The AF… series 1-stack 3-pole contactors are of the block type design. – Main poles and auxiliary contact blocks: 3 main poles, 1 built-in auxiliary contact, front and side-mounted add-on auxiliary contact blocks (mechanically-linked auxiliary contacts compliant with Annex L of IEC 60947-5-1. N.C. mirror contacts compliant with Annex F of IEC 60947-4-1) – Control circuit: AC or DC operated – Accessories: a wide range of accessories is available.
Categories
- Products » Low Voltage Products and Systems » Control Products » Contactors » Block Contactors
Technical
-
-
- Number of Main Contacts NO:
- 3
-
- Number of Main Contacts NC:
- 0
-
- Number of Auxiliary Contacts NO:
- 1
-
- Number of Auxiliary Contacts NC:
- 0
-
- Standards:
- IEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-1, UL 508, CSA C22.2 N°14
-
- Rated Operational Voltage:
- Auxiliary Circuit 690 V
Main Circuit 690 V
-
- Rated Frequency (f):
- Auxiliary Circuit 50 / 60 Hz
Main Circuit 50 / 60 Hz
-
- Conventional Free-air Thermal Current (Ith):
- acc. to IEC 60947-4-1, Open Contactors q = 40 °C 35 A
acc. to IEC 60947-5-1, q = 40 °C 16 A
-
- Rated Operational Current AC-1 (Ie):
- (690 V) 40 °C 28
(690 V) 60 °C 28 A
(690 V) 70 °C 24
-
- Rated Operational Current AC-3 (Ie):
- (415 V) 60 °C 12 A
(440 V) 60 °C 12 A
(500 V) 60 °C 12.5 A
(690 V) 60 °C 9 A
(380 / 400 V) 60 °C 12 A
(220 / 230 / 240 V) 60 °C 12 A
-
- Rated Operational Power AC-3 (Pe):
- (400 V) 5.5 kW
(415 V) 5.5 kW
(440 V) 5.5 kW
(500 V) 7.5 kW
(690 V) 7.5 kW
(380 / 400 V) 5.5 kW
(220 / 230 / 240 V) 3 kW
-
- Rated Operational Current AC-15 (Ie):
- (500 V) 2 A
(690 V) 2 A
(24 / 127 V) 6 A
(220 / 240 V) 4 A
(400 / 440 V) 3 A
-
-
- Terminal Type:
- Screw Terminals
Technical UL/CSA
-
- General Use Rating UL/CSA:
- (600 V AC) 28 A
-
- Horsepower Rating UL/CSA:
- (120 V AC) Single Phase 1 hp
(200 … 208 V AC) Three Phase 3 hp
(220 … 240 V AC) Three Phase 3 hp
(240 V AC) Single Phase 2 hp
(440 … 480 V AC) Three Phase 7-1/2 hp
(550 … 600 V AC) Three Phase 10 hp
-
- Tightening Torque UL/CSA:
- Auxiliary Circuit 11 IA
Control Circuit 11 IA
Main Circuit 13 IA
Reviews
There are no reviews yet.