General Information
-
- Extended Product Type:
- MS450-40
-
- Product ID:
- 1SAM450000R1005
-
- EAN:
- 4013614265174
-
- Catalog Description:
- MS450-40 Manual Motor Starter
-
- Long Description:
- The MS450-40 manual motor starter is a 55 mm width devices with a rated operational current of Ie = 40.0 A. This device is used to manually switch on and off motors and to protect them reliably and without the need for a fuse from short-circuits, overload and phase failures. The manual motor starter offers a rated service short-circuit breaking capacity Ics = 25 kA at 400 VAC and the trip class 10. Further features are the build-in disconnect function, temperature compensation, trip-free mechanism and a rotary handle with a clear switch position indication. The manual motor starter is suitable for three- and single-phase applications. The handle is lockable to protect against unauthorized changes. Auxiliary contacts, signaling contacts, undervoltage releases, shunt trips, 3-phase bus bars, power in-feed blocks are available as accessory.
Categories
- Products » Low Voltage Products and Systems » Circuit Breakers » Manual Motor Starters
- Products » Low Voltage Products and Systems » Control Products » Manual Motor Starters » Manual Motor Starters
-
- Data Sheet, Technical Information:
- 1SBC100173C0201
-
- Data Sheet, Technical Information (Part 3):
- 9AKK105713A1100
-
- Instructions and Manuals:
- 1SAM407001R1001
-
- Instructions and Manuals (Part 2):
- 2CDC131017M5701
-
- Time-Current Characteristic Curve:
- 1SAM400501F0005
Dimensions
-
- Product Net Width:
- 55 mm
-
- Product Net Height:
- 140 mm
-
- Product Net Depth / Length:
- 149 mm
-
- Product Net Weight:
- 1.047 kg
Technical
-
- Rated Service Short-Circuit Breaking Capacity (Ics):
- (230 V AC) 100 kA
(400 V AC) 25 kA
(440 V AC) 15 kA
(500 V AC) 5 kA
(690 V AC) 2 kA
-
- Rated Ultimate Short-Circuit Breaking Capacity (Icu):
- (230 V AC) 100 kA
(400 V AC) 50 kA
(440 V AC) 50 kA
(500 V AC) 10 kA
(690 V AC) 4 kA
-
- Rated Instantaneous Short-Circuit Current Setting (Ii):
- 520 A
-
- Setting Range:
- 28 … 40 A
-
- Rated Operational Power AC-3 (Pe):
- (400 V) Three Phase 18.5 kW
-
- Rated Operational Voltage:
- Main Circuit 690 V AC
Main Circuit 450 V DC
-
- Rated Operational Current (Ie):
- 40 A
-
- Rated Operational Current AC-3 (Ie):
- 40 A
-
- Rated Frequency (f):
- Main Circuit 50 Hz
Main Circuit 60 Hz
-
- Rated Impulse Withstand Voltage (Uimp):
- Main Circuit 6 kV
-
- Rated Insulation Voltage (Ui):
- 690 V
-
- Power Loss:
- at Rated Operating Conditions per Pole 3.2 … 6.7 W
-
- Number of Poles:
- 3
-
- Conventional Free-air Thermal Current (Ith):
- Main Circuit 40 A
-
- Degree of Protection:
- Housing IP20
Main Circuit Terminals IP00
-
- Pollution Degree:
- 3
-
- Electrical Durability:
- 25000 cycle
-
- Mechanical Durability:
- 50000 cycle
-
- Connecting Capacity Main Circuit:
- Flexible with Ferrule 1x 0.75 … 25 mm²
Flexible with Ferrule 2x 0.75 … 16 mm²
Solid 1/2x 0.75 … 16 mm²
Stranded 1x 0.75 … 35 mm²
Stranded 2x 0.75 … 25 mm²
-
- Tightening Torque:
- Main Circuit 3 … 4.5 N·m
-
- Wire Stripping Length:
- Main Circuit 13 mm
-
- Recommended Screw Driver:
- M5
Pozidriv 2
-
- Mounting Position:
- Position 1 to 6
-
- Mounting on DIN Rail:
- TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
-
- Actuator Type:
- Rotary Handle
-
- Contact Position Indication:
- ON / OFF / TRIP
-
- Standards:
- CSA 22.2 No. 14
IEC/EN 60947-1
IEC/EN 60947-2
IEC/EN 60947-4-1
UL 508
Technical UL/CSA
-
- Maximum Operating Voltage UL/CSA:
- Main Circuit 600 V AC
-
- Ampere Rating UL/CSA:
- 40 A
-
- Horsepower Rating UL/CSA:
- (200 V AC) Three Phase 10 Hp
(208 V AC) Three Phase 10 Hp
(220 … 240 V AC) Three Phase 15 Hp
(440 … 480 V AC) Three Phase 30 Hp
(550 … 600 V AC) Three Phase 40 Hp
-
- General Use Rating UL/CSA:
- (600 V AC) 40 A
-
- Connecting Capacity Main Circuit UL/CSA:
- Flexible 2x 18-2 AWG
Stranded 2x 18-2 AWG
-
- Tightening Torque UL/CSA:
- Main Circuit 27 … 40 in·lb
Reviews