General Information
-
- Extended Product Type:
- TA25DU-19M
-
- Product ID:
- 1SAZ211201R2047
-
- EAN:
- 4013614482564
-
- Catalog Description:
- TA25DU-19M Thermal Overload Relays
-
- Long Description:
- TA25DU-19M (13.0-19.0A) thermal overload relay is an economic electromechanical protection device for the main circuit. It offers reliable and fast protection for motors in the event of overload or phase failure. The device has trip class 10A. Further features are the temperature compensation, trip contact (NC), signal contact (NO), automatic- or manual reset selectable, trip-free mechanism, STOP- and Test function and a trip indication. The overload relays are connected directly to the block contactors. Single mounting kits are available as accessory.
Categories
- Products » Low Voltage Products and Systems » Control Products » Contactors » Thermal Overload Relays
Technical
-
- Setting Range:
- 13.0 … 19.0 A
-
- Rated Operational Voltage:
- Auxiliary Circuit 440/500 V AC/DC
Main Circuit 690 V AC
-
- Rated Operational Current (Ie):
- 19 A
-
- Rated Operational Current AC-3 (Ie):
- 19 A
-
- Rated Frequency (f):
- Auxiliary Circuit 50 Hz
Auxiliary Circuit 60 Hz
Auxiliary Circuit DC
Main Circuit 60 Hz
Main Circuit 50 Hz
Main Circuit DC
-
- Rated Impulse Withstand Voltage (Uimp):
- Auxiliary Circuit 6 kV
Main Circuit 6 kV
-
- Rated Insulation Voltage (Ui):
- 690 V
-
- Number of Poles:
- 3
-
- Number of Auxiliary Contacts NC:
- 1
-
- Number of Auxiliary Contacts NO:
- 1
-
- Number of Protected Poles:
- 3
-
- Conventional Free-air Thermal Current (Ith):
- Auxiliary Circuit NC 5 A
Auxiliary Circuit NO 5 A
-
- Rated Operational Current AC-15 (Ie):
- (120 V) NC 3.000 A
(120 V) NO 1.500 A
(240 V) NC 3.000 A
(240 V) NO 1.500 A
(400 V) NC 1.900 A
(400 V) NO 1.000 A
(440 V) NC 1.000 A
(440 V) NO 1.000 A
(500 V) NC 1.000 A
(500 V) NO 1.000 A
-
- Rated Operational Current DC-13 (Ie):
- (125 V) NC 0.250 A
(125 V) NO 0.250 A
(24 V) NC 1.250 A
(24 V) NO 1.250 A
(250 V) NC 0.120 A
(250 V) NO 0.040 A
(60 V) NC 0.250 A
(60 V) NO 0.250 A
-
- Degree of Protection:
- Housing IP20
Main Circuit Terminals IP10
-
- Pollution Degree:
- 3
-
- Connecting Capacity Auxiliary Circuit:
- Flexible 1/2x 0.75 … 2.5 mm²
Rigid 1/2x 0.75 … 4 mm²
-
- Connecting Capacity Main Circuit:
- Flexible with Ferrule 1x 0.75 … 4 mm²
Flexible with Ferrule 2x 0.75 … 4 mm²
Flexible 1x 0.75 … 4 mm²
Flexible 2x 0.75 … 4 mm²
Rigid 1x 0.75 … 4 mm²
Rigid 2x 0.75 … 4 mm²
-
- Tightening Torque:
- Auxiliary Circuit 1 … 1.3 N·m
Main Circuit 1.5 … 1.9 N·m
-
- Wire Stripping Length:
- Auxiliary Circuit 9 mm
Main Circuit 12 mm
-
- Recommended Screw Driver:
- Auxiliary Circuit Pozidriv 1
Main Circuit Pozidriv 2
-
- Mounting Position:
- Position 1 to 4
-
- Power Loss:
- at Rated Operating Conditions per Pole 1.1 … 2.3 W
-
- Suitable For:
- AX09
AX12
AX18
AX25
AX32
AX40
-
- Standards:
- CSA 22.2 No. 14
IEC/EN 60947-1
IEC/EN 60947-4-1
IEC/EN 60947-5-1
UL 508
Technical UL/CSA
-
- Maximum Operating Voltage UL/CSA:
- Main Circuit 600 V AC
-
- Ampere Rating UL/CSA:
- 19 A
-
- Contact Rating UL/CSA:
- (NC:) B600
(NO:) C600
-
- Connecting Capacity Main Circuit UL/CSA:
- Flexible 1/2x 16-8 AWG
Stranded 1/2x 16-8 AWG
-
- Connecting Capacity Auxiliary Circuit UL/CSA:
- Flexible 1/2x 18-14 AWG
Stranded 1/2x 18-14 AWG
-
- Tightening Torque UL/CSA:
- Auxiliary Circuit 12 in·lb
Main Circuit 12 in·lb