1SFL477001R7011 AF145-30-11 100-250V 50/60Hz / 100-250V DC Contactor

Original price was: ₦157,125.00.Current price is: ₦155,125.00. 7.5% VAT

AF145-30-11 100-250V 50/60Hz / 100-250V DC Contactor

SKU: 1SFL477001R7011 Category:

General Information

  • Extended Product Type:
    AF145-30-11-70
  • Product ID:
    1SFL477001R7011
  • EAN:
    7320500220191
  • Catalog Description:
    AF145-30-11 100-250V 50/60Hz / 100-250V DC Contactor
  • Long Description:
    A 3-phase Contactor suitable for various applications such as Motor starting, Isolation, By-pass and Distribution application up to max 1000 V. Operated with wide control voltage range 100-250 V, AC/DC

Categories

  • Products » Low Voltage Products and Systems » Control Products » Contactors » Block Contactors

Technical

  • Number of Main Contacts NO:
    3
  • Number of Main Contacts NC:
    0
  • Number of Auxiliary Contacts NO:
    1
  • Number of Auxiliary Contacts NC:
    1
  • Rated Operational Voltage:
    Main Circuit 690 V
  • Rated Frequency (f):
    Main Circuit 50/60 Hz
  • Conventional Free-air Thermal Current (Ith):
    acc. to IEC 60947-4-1, Open Contactors q = 40 °C 250 A
  • Rated Operational Current AC-1 (Ie):
    (1000 V) 40 °C 180 A
    (1000 V) 55 °C 180 A
    (1000 V) 70 °C 180 A
    (690 V) 40 °C 250
    (690 V) 55 °C 230
    (690 V) 70 °C 180
  • Rated Operational Current AC-3 (Ie):
    (415 V) 55 °C 145 A
    (440 V) 55 °C 145 A
    (500 V) 55 °C 145 A
    (690 V) 55 °C 120 A
    (1000 V) 55 °C 80 A
    (380 / 400 V) 55 °C 145 A
    (220 / 230 / 240 V) 55 °C 145
  • Rated Operational Power AC-3 (Pe):
    (415 V) 75 kW
    (440 V) 75 kW
    (500 V) 90 kW
    (690 V) 110 kW
    (1000 V) 110 kW
    (380 / 400 V) 75 kW
    (220 / 230 / 240 V) 45 kW
  • Rated Breaking Capacity AC-3 acc. to IEC 60947-4-1:
    8 x Ie AC-3
  • Rated Making Capacity AC-3 acc. to IEC 60947-4-1:
    10 x Ie AC-3
  • Short-Circuit Protective Devices:
    gG Type Fuses 315 A
  • Rated Short-time Withstand Current (Icw):
    at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 1200 A
    at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 280 A
    at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 600 A
    at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1800 A
    at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 800 A
  • Maximum Breaking Capacity:
    cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1500 A
    cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 1200 A
  • Maximum Electrical Switching Frequency:
    (AC-1) 300 cycles per hour
    (AC-2 / AC-4) 150 cycles per hour
    (AC-3) 300 cycles per hour
  • Rated Operational Current DC-1 (Ie):
    (110 V) 2 Poles in Series, 40 °C 250 A
    (220 V) 3 Poles in Series, 40 °C 250 A
  • Rated Operational Current DC-3 (Ie):
    (110 V) 2 Poles in Series, 40 °C 250 A
    (220 V) 3 Poles in Series, 40 °C 250 A
  • Rated Operational Current DC-5 (Ie):
    (110 V) 2 Poles in Series, 40 °C 250 A
    (220 V) 3 Poles in Series, 40 °C 250 A
  • Rated Insulation Voltage (Ui):
    acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
    acc. to UL/CSA 600 V
  • Rated Impulse Withstand Voltage (Uimp):
    Main Circuit 8 kV
  • Mechanical Durability:
    5 million
  • Maximum Mechanical Switching Frequency:
    300 cycles per hour
  • Coil Operating Limits:
    (acc. to IEC 60947-4-1) 0.85 x Uc Min. … 1.1 x Uc Max. (at θ ≤ 70 °C)
  • Rated Control Circuit Voltage (Uc):
    50 Hz 100 … 250 V
    60 Hz 100 … 250 V
    DC Operation 100 … 250 V
  • Coil Consumption:
    Holding at Max. Rated Control Circuit Voltage 50 Hz 12 V·A
    Holding at Max. Rated Control Circuit Voltage 60 Hz 12 V·A
    Holding at Max. Rated Control Circuit Voltage DC 2 W
    Pull-in at Max. Rated Control Circuit Voltage 50 Hz 430 V·A
    Pull-in at Max. Rated Control Circuit Voltage 60 Hz 430 V·A
    Pull-in at Max. Rated Control Circuit Voltage DC 500 W
  • Operate Time:
    Between Coil De-energization and NC Contact Closing 40 …. 50 ms
    Between Coil De-energization and NO Contact Opening 43 … 53 ms
    Between Coil Energization and NC Contact Opening 45 … 85 ms
    Between Coil Energization and NO Contact Closing 50 … 90 ms
  • Connecting Capacity Main Circuit:
    Bar 24 mm²
    Rigid Al-Cable 1 x 25 … 150 mm²
    Rigid Cu-Cable 1 x 6 … 185 mm²
  • Connecting Capacity Auxiliary Circuit:
    Flexible with Ferrule 2x 0.75 … 2.5 mm²
    Flexible with Insulated Ferrule 1x 0.75 … 2.5 mm²
    Flexible 2×0.75 … 2.5 mm²
    Solid 2 x 1 … 4 mm²
    Stranded 2 x 1 …. 4 mm²
  • Degree of Protection:
    acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
    acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
  • Terminal Type:
    Main Circuit: Bars

Technical UL/CSA

  • Maximum Operating Voltage UL/CSA:
    Main Circuit 600 V
  • General Use Rating UL/CSA:
    (600 V AC) 230 A
  • Horsepower Rating UL/CSA:
    (200 V AC) Three Phase 40 hp
    (208 V AC) Three Phase 40 hp
    (220 … 240 V AC) Three Phase 50 hp
    (440 … 480 V AC) Three Phase 100 hp
    (550 … 600 V AC) Three Phase 125 hp