Sale!

ATV212HD55N4 Variable speed drive ATV212 – 55kW – 75hp – 480V – 3ph – EMC – IP21

2,816,135.00 7.5% VAT

Variable speed drive ATV212 – 55kW – 75hp – 480V – 3ph – EMC – IP21

 

Available on back-order

SKU: ATV212HD55N4 Category: Tag:
Main
range of product
Altivar 212
product or component type
Variable speed drive
device short name
ATV212
product destination
Asynchronous motors
product specific application
Pumps and fans in HVAC
assembly style
With heat sink
network number of phases
3 phases
motor power kW
55 kW
motor power hp
75 hp
[Us] rated supply voltage
380…480 V – 15…10 %
supply voltage limits
323…528 V
supply frequency
50…60 Hz – 5…5 %
EMC filter
Class C2 EMC filter integrated
line current
102.7 A at 380 V
89 A at 480 V
Complementary
apparent power
76.3 kVA at 380 V
prospective line Isc
22 kA
continuous output current
116 A at 380 V
116 A at 460 V
maximum transient current
127.6 A for 60 s
speed drive output frequency
0.5…200 Hz
nominal switching frequency
8 kHz
switching frequency
6…16 kHz adjustable
8…16 kHz with derating factor
speed range
1…10
speed accuracy
+/- 10 % of nominal slip 0.2 Tn to Tn
torque accuracy
+/- 15 %
transient overtorque
120 % of nominal motor torque +/- 10 % for 60 s
asynchronous motor control profile
Voltage/frequency ratio, automatic IR compensation (U/f + automatic Uo)
Flux vector control without sensor, standard
Voltage/frequency ratio, 5 points
Voltage/frequency ratio – Energy Saving, quadratic U/f
Voltage/frequency ratio, 2 points
regulation loop
Adjustable PI regulator
motor slip compensation
Adjustable
Automatic whatever the load
Not available in voltage/frequency ratio motor control
local signalling
1 LED (red) for DC bus energized
output voltage
<= power supply voltage
isolation
Electrical between power and control
type of cable
Without mounting kit: 1 wire(s)IEC cable at 45 °C, copper 90 °C / XLPE/EPR
Without mounting kit: 1 wire(s)IEC cable at 45 °C, copper 70 °C / PVC
With UL Type 1 kit: 3 wire(s)UL 508 cable at 40 °C, copper 75 °C / PVC
electrical connection
VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES: terminal 2.5 mm² / AWG 14
L1/R, L2/S, L3/T: terminal 150 mm² (300 kcmil)
tightening torque
0.6 N.m (VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES)
41 N.m, 360 lb.in (L1/R, L2/S, L3/T)
supply
Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 A, protection type: overload and short-circuit protection
Internal supply: 24 V DC (21…27 V), <200 A, protection type: overload and short-circuit protection
analogue input number
2
analogue input type
VIA switch-configurable voltage: 0…10 V DC 24 V max, impedance: 30000 Ohm, resolution 10 bits
VIB configurable voltage: 0…10 V DC 24 V max, impedance: 30000 Ohm, resolution 10 bits
VIB configurable PTC probe: 0…6 probes, impedance: 1500 Ohm
VIA switch-configurable current: 0…20 mA, impedance: 250 Ohm, resolution 10 bits
sampling duration
2 ms +/- 0.5 ms F discrete
2 ms +/- 0.5 ms R discrete
2 ms +/- 0.5 ms RES discrete
3.5 ms +/- 0.5 ms VIA analog
22 ms +/- 0.5 ms VIB analog
response time
FM 2 ms, tolerance +/- 0.5 ms for analog output(s)
FLA, FLC 7 ms, tolerance +/- 0.5 ms for discrete output(s)
FLB, FLC 7 ms, tolerance +/- 0.5 ms for discrete output(s)
RY, RC 7 ms, tolerance +/- 0.5 ms for discrete output(s)
accuracy
+/- 0.6 % (VIA) for a temperature variation 60 °C
+/- 0.6 % (VIB) for a temperature variation 60 °C
+/- 1 % (FM) for a temperature variation 60 °C
linearity error
VIA: +/- 0.15 % of maximum value for input
VIB: +/- 0.15 % of maximum value for input
FM: +/- 0.2 % for output
analogue output number
1
analogue output type
FM switch-configurable voltage 0…10 V DC, impedance: 7620 Ohm, resolution 10 bits
FM switch-configurable current 0…20 mA, impedance: 970 Ohm, resolution 10 bits
discrete output number
2
discrete output type
Configurable relay logic: (FLA, FLC) NO – 100000 cycles
Configurable relay logic: (FLB, FLC) NC – 100000 cycles
Configurable relay logic: (RY, RC) NO – 100000 cycles
minimum switching current
3 mA at 24 V DC for configurable relay logic
maximum switching current
5 A at 250 V AC on resistive load – cos phi = 1 – L/R = 0 ms (FL, R)
5 A at 30 V DC on resistive load – cos phi = 1 – L/R = 0 ms (FL, R)
2 A at 250 V AC on inductive load – cos phi = 0.4 – L/R = 7 ms (FL, R)
2 A at 30 V DC on inductive load – cos phi = 0.4 – L/R = 7 ms (FL, R)
discrete input type
F programmable 24 V DC, with level 1 PLC, impedance: 4700 Ohm
R programmable 24 V DC, with level 1 PLC, impedance: 4700 Ohm
RES programmable 24 V DC, with level 1 PLC, impedance: 4700 Ohm
discrete input logic
Positive logic (source) (F, R, RES), <= 5 V (state 0), >= 11 V (state 1)
Negative logic (sink) (F, R, RES), >= 16 V (state 0), <= 10 V (state 1)
acceleration and deceleration ramps
Automatic based on the load
Linear adjustable separately from 0.01 to 3200 s
braking to standstill
By DC injection
protection type
Overheating protection: drive
Thermal power stage: drive
Short-circuit between motor phases: drive
Input phase breaks: drive
Overcurrent between output phases and earth: drive
Overvoltages on the DC bus: drive
Break on the control circuit: drive
Against exceeding limit speed: drive
Line supply overvoltage and undervoltage: drive
Line supply undervoltage: drive
Against input phase loss: drive
Thermal protection: motor
Motor phase break: motor
With PTC probes: motor
dielectric strength
3535 V DC between earth and power terminals
5092 V DC between control and power terminals
insulation resistance
>= 1 mOhm 500 V DC for 1 minute
frequency resolution
Display unit: 0.1 Hz
Analog input: 0.024/50 Hz
communication port protocol
METASYS N2
BACnet
LonWorks
APOGEE FLN
Modbus
connector type
1 open style
1 RJ45
physical interface
2-wire RS 485
transmission frame
RTU
transmission rate
9600 bps or 19200 bps
data format
8 bits, 1 stop, odd even or no configurable parity
type of polarization
No impedance
number of addresses
1…247
communication service
Time out setting from 0.1 to 100 s
Write multiple registers (16) 2 words maximum
Write single register (06)
Read holding registers (03) 2 words maximum
Read device identification (43)
Monitoring inhibitable
option card
Communication card for LonWorks
operating position
Vertical +/- 10 degree
width
320 mm
height
630 mm
depth
290 mm
power dissipation in W
1455 W
air flow
498 m3/h
functionality
Mid
specific application
HVAC
IP degree of protection
IP21
Variable speed drive application selection
Building – HVAC Compressor for scroll
Building – HVAC Fan
Building – HVAC Pump
Motor power range AC-3
55…100 kW at 380…440 V 3 phases
55…100 kW at 480…500 V 3 phases
motor starter type
Variable speed drive

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.