Sale!

ATV340U30N4E Variable speed drive – 3kW- 400V – 3 phases – ATV340 Ethernet

Original price was: ₦1,714,289.13.Current price is: ₦1,371,431.30. 7.5% VAT

Variable speed drive – 3kW- 400V – 3 phases – ATV340 Ethernet

 

SKU: ATV340U30N4E Category:
Main
range of product
Altivar Machine ATV340
product or component type
Variable speed drive
product specific application
Machine
variant
Standard version
mounting mode
Cabinet mount
communication port protocol
Modbus serial
Modbus TCP
Ethernet/IP
option card
Communication module, Profibus DP V1
Communication module, Profinet
Communication module, DeviceNet
Communication module, CANopen
Communication module, EtherCAT
network number of phases
3 phases
supply frequency
50…60 Hz +/- 5 %
[Us] rated supply voltage
380…480 V – 15…10 %
nominal output current
7.2 A
motor power kW
4 kW for normal duty
3 kW for heavy duty
motor power hp
3 hp for heavy duty
5 hp for normal duty
EMC filter
Class C3 EMC filter integrated
IP degree of protection
IP20
Complementary
discrete input number
5
discrete input type
PTI programmable as pulse input: 0…30 kHz, 24 V DC (30 V)
DI1…DI5 safe torque off, 24 V DC (30 V), impedance: 3.5 kOhm
programmable
number of preset speeds
16 preset speeds
discrete output number
2.0
discrete output type
Programmable output DQ1, DQ2 30 V DC 100 mA
analogue input number
2
analogue input type
AI1 software-configurable current: 0…20 mA, impedance: 250 Ohm, resolution 12 bits
AI1 software-configurable temperature probe or water level sensor
AI1 software-configurable voltage: 0…10 V DC, impedance: 31.5 kOhm, resolution 12 bits
AI2 software-configurable voltage: – 10…10 V DC, impedance: 31.5 kOhm, resolution 12 bits
analogue output number
2
analogue output type
Software-configurable voltage AQ1: 0…10 V DC impedance 470 Ohm, resolution 10 bits
Software-configurable current AQ1: 0…20 mA impedance 500 Ohm, resolution 10 bits
relay output number
2
output voltage
<= power supply voltage
relay output type
Relay outputs R1A
Relay outputs R1C electrical durability 100000 cycles
Relay outputs R2A
Relay outputs R2C electrical durability 100000 cycles
maximum switching current
Relay output R1C on resistive load, cos phi = 1: 3 A at 250 V AC
Relay output R1C on resistive load, cos phi = 1: 3 A at 30 V DC
Relay output R1C on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC
Relay output R1C on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC
Relay output R2C on resistive load, cos phi = 1: 5 A at 250 V AC
Relay output R2C on resistive load, cos phi = 1: 5 A at 30 V DC
Relay output R2C on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC
Relay output R2C on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC
minimum switching current
Relay output R1B: 5 mA at 24 V DC
Relay output R2C: 5 mA at 24 V DC
physical interface
2-wire RS 485
connector type
3 RJ45
method of access
Slave Modbus RTU
Slave Modbus TCP
transmission rate
4.8 kbit/s
9.6 kbit/s
19.2 kbit/s
38.4 kbit/s
transmission frame
RTU
number of addresses
1…247
data format
8 bits, configurable odd, even or no parity
type of polarization
No impedance
4 quadrant operation possible
True
asynchronous motor control profile
Optimized torque mode
Variable torque standard
Constant torque standard
synchronous motor control profile
Reluctance motor
Permanent magnet motor
pollution degree
2 conforming to EN/IEC 61800-5-1
maximum output frequency
0.599 kHz
acceleration and deceleration ramps
S, U or customized
Linear adjustable separately from 0.01…9999 s
motor slip compensation
Adjustable
Not available in permanent magnet motor law
Can be suppressed
Automatic whatever the load
switching frequency
2…16 kHz adjustable
7…16 kHz with derating factor
nominal switching frequency
4 kHz
braking to standstill
By DC injection
brake chopper integrated
True
line current
8.6 A at 380 V (normal duty)
6.8 A at 480 V (normal duty)
10.7 A at 380 V (heavy duty)
8.5 A at 480 V (heavy duty)
line current
10.7 A at 380 V without line choke (heavy duty)
8.5 A at 480 V without line choke (heavy duty)
8.6 A at 380 V with external line choke (normal duty)
6.8 A at 480 V with external line choke (normal duty)
6.6 A at 380 V with external line choke (heavy duty)
5.3 A at 480 V with external line choke (heavy duty)
maximum input current
10.7 A
maximum output voltage
480 V
apparent power
6.7 kVA at 480 V (normal duty)
7.1 kVA at 480 V (heavy duty)
maximum transient current
10.2 A during 60 s (normal duty)
12.6 A during 2 s (normal duty)
13 A during 2 s (heavy duty)
11 A during 60 s (heavy duty)
electrical connection
Screw terminal, clamping capacity: 1.5…4 mm² for line side
Screw terminal, clamping capacity: 4…6 mm² for DC bus
Screw terminal, clamping capacity: 1.5…4 mm² for motor
Screw terminal, clamping capacity: 0.2…2.5 mm² for control
prospective line Isc
5 kA
base load current at high overload
7.2 A
base load current at low overload
9.3 A
power dissipation in W
Natural convection: 78 W at 380 V, switching frequency 4 kHz (heavy duty)
Forced convection: 78 W at 380 V, switching frequency 4 kHz (heavy duty)
Natural convection: 96 W at 380 V, switching frequency 4 kHz (normal duty)
Forced convection: 96 W at 380 V, switching frequency 4 kHz (normal duty)
electrical connection
Line side: screw terminal1.5…4 mm²/AWG 14…AWG 12
DC bus: screw terminal4…6 mm²/AWG 12…AWG 10
Motor: screw terminal1.5…4 mm²/AWG 14…AWG 12
Control: screw terminal0.2…2.5 mm²/AWG 24…AWG 12
with safety function Safely Limited Speed (SLS)
True
with safety function Safe brake management (SBC/SBT)
True
with safety function Safe Operating Stop (SOS)
False
with safety function Safe Position (SP)
False
with safety function Safe programmable logic
False
with safety function Safe Speed Monitor (SSM)
False
with safety function Safe Stop 1 (SS1)
True
with sft fct Safe Stop 2 (SS2)
False
with safety function Safe torque off (STO)
True
with safety function Safely Limited Position (SLP)
False
with safety function Safe Direction (SDI)
False
protection type
Thermal protection: motor
Safe torque off: motor
Motor phase loss: motor
Thermal protection: drive
Safe torque off: drive
Overheating: drive
Overcurrent: drive
Output overcurrent between motor phase and earth: drive
Output overcurrent between motor phases: drive
Short-circuit between motor phase and earth: drive
Short-circuit between motor phases: drive
Motor phase loss: drive
DC Bus overvoltage: drive
Line supply overvoltage: drive
Line supply undervoltage: drive
Input supply loss: drive
Exceeding limit speed: drive
Break on the control circuit: drive
width
85.0 mm
height
270.0 mm
depth
232.5 mm
net weight
2.2 kg
continuous output current
9.3 A at 4 kHz for normal duty
7.2 A at 4 kHz for heavy duty

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.