Lauritz Knudsen Manual Changeover Switch, C-Line, 400A, 415V AC | Frame 4 | 4 Pole | SS Enclosure Extended Handle| Load‑Handling Capability

Original price was: ₦900,000.00.Current price is: ₦863,000.00.

About the Product

The Lauritz Knudsen C-Line Manual Changeover Switch FR4 400A 4P 415V AC with SS (stainless steel) enclosure is a robust & high-capacity switching solution engineered for safe transfer of electrical load between two power sources such as mains supply & generator backup.

This model features a heavy-duty stainless steel enclosure that provides superior protection against dust, moisture, corrosion, & harsh environmental conditions. The extended handle allows smooth & safe external operation without opening the enclosure, improving usability & operator safety.

As part of the FR4 series, it is designed for high-load & demanding industrial environments. Its 4-pole (4P) configuration ensures complete isolation of all conductors including neutral, delivering enhanced safety, reliability, & consistent performance.

Purpose & Function

This enclosed manual changeover switch ensures reliable & safe power control:

• Transfers load between mains & generator supply

• Provides complete electrical isolation during switching

• Enables safe external operation via extended handle

• Ensures continuity of power during source transitions

• Enhances safety with protective enclosure

Electrical Configuration

• Type: Manual Changeover Switch

• Series: C-Line FR4

• Current rating: 400A

• Rated voltage: 415V AC

• Poles: 4 Pole (4P)

• Enclosure: Stainless Steel (SS)

• Operation: Extended handle

• Function: Power source switching & isolation

Construction & Design

The switch is engineered for durability & high-performance use:

• Stainless steel enclosure for corrosion resistance & protection

• Heavy-duty industrial-grade construction

• Extended handle for convenient external operation

• Compact yet robust design suitable for large panels

• High-quality contact system for consistent & reliable switching

Safety & Protection

• SS enclosure protects against dust, moisture, & environmental damage

• 4-pole configuration ensures complete circuit isolation

• Reduces risk of electrical faults & accidental contact

• Improves operator safety during switching

• Ensures long-term performance in harsh environments

Mounting & Installation

• Suitable for wall or panel mounting

• Enclosed design supports installation in exposed or semi-outdoor environments

• Extended handle enables operation without opening enclosure

• Compatible with standard industrial electrical systems

• Supports organized & secure internal wiring

Application Domains

• Industrial power distribution systems

• Commercial infrastructure & facilities

• Generator backup systems

• Outdoor & semi-outdoor installations

• Electrical control panels in harsh environments

• Manufacturing & processing plants

Key Features

• 400A current rating for high-capacity applications

• 415V AC operation for three phase systems

• 4-pole configuration for complete electrical isolation

• Stainless steel enclosure for enhanced durability & protection

• Extended handle for safe external operation

• Heavy-duty industrial-grade design

Applications

• Generator changeover panels

• Industrial distribution boards

• Commercial electrical systems

• Outdoor electrical installations

• Backup power management systems

FAQs

1. What is the purpose of this changeover switch?
Ans: It is used to safely transfer electrical load between two sources such as mains & generator.

2. What does 4P mean?
Ans: 4P (four-pole) means all conductors including neutral are fully isolated for maximum safety.

3. Why is an SS enclosure used?
Ans: It protects against dust, moisture, corrosion, & external damage, ensuring durability in harsh environments.

4. What is the benefit of the extended handle?
Ans: It allows the switch to be operated externally without opening the enclosure, improving safety & convenience.

5. Can this be used outdoors?
Ans: Yes, the enclosed design makes it suitable for outdoor & semi-outdoor applications.

6. Is this suitable for industrial use?
Ans: Yes, it is designed for heavy-duty industrial & commercial applications.

7. Why is full isolation important?
Ans: Full isolation ensures safe operation & maintenance by completely disconnecting the electrical circuit.

Rated Operational Current (A) 400
Conformance to Standards IS/IEC 60947-3, EN 60947-3
Utilization Category AC-23A
Rated operational voltage (Ue) 415V
Operating Frequency(Hz) 50/60
Mechanical Life (No. of operating cycles) 10000
Rated Insulation Voltage Ui (V) 1000
Short Time Withstand for 1sec (kA) 22
Rated Operational Power (kW) 225
Rated Breaking Capacity@AC-23A (A) 3200