LC1D40BD CONTACTOR 600VAC 40AMP IEC +OPTIONS

Original price was: ₦322,010.00.Current price is: ₦257,608.00. 7.5% VAT

CONTACTOR 600VAC 40AMP IEC +OPTIONS

SKU: LC1D40BD Category:
Main
range of product
TeSys D
range
TeSys
product or component type
Contactor
device short name
LC1D
contactor application
Resistive load
Motor control
utilisation category
AC-2
AC-3
AC-1
AC-4
control circuit type
DC standard
poles description
3P
pole contact composition
3 NO
[Ie] rated operational current
40 A (at <60 °C) at <= 440 V AC AC-3 for power circuit
60 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
motor power kW
18.5 kW at 380…400 V AC 50 Hz (AC-3)
22 kW at 500 V AC 50 Hz (AC-3)
30 kW at 660…690 V AC 50 Hz (AC-3)
22 kW at 1000 V AC 50 Hz (AC-3)
22 kW at 415 V AC 50 Hz (AC-3)
22 kW at 440 V AC 50 Hz (AC-3)
11 kW at 220…230 V AC 50 Hz (AC-3)
9 kW at 400 V AC 50 Hz (AC-4)
Complementary
coil technology
Built-in bidirectional peak limiting diode suppressor
Front cover
With
motor power hp
3 hp at 115 V AC 60 Hz for 1 phase motors
5 hp at 230/240 V AC 60 Hz for 1 phase motors
10 hp at 200/208 V AC 60 Hz for 3 phases motors
10 hp at 230/240 V AC 60 Hz for 3 phases motors
30 hp at 460/480 V AC 60 Hz for 3 phases motors
30 hp at 575/600 V AC 60 Hz for 3 phases motors
auxiliary contacts type
type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1
type mirror contact 1 NC conforming to IEC 60947-4-1
auxiliary contact composition
1 NO + 1 NC
[Uc] control circuit voltage
24 V DC
time constant
34 ms
[Ui] rated insulation voltage
Control circuit: 600 V CSA certified
Control circuit: 600 V UL certified
Power circuit: 600 V CSA certified
Power circuit: 600 V UL certified
Control circuit: 690 V conforming to IEC 60947-1
Power circuit: 690 V conforming to IEC 60947-1
Power circuit: 1000 V conforming to IEC 60947-4-1
[Uimp] rated impulse withstand voltage
8 kV conforming to IEC 60947
overvoltage category
III
mounting support
Rail
Plate
flame retardance
V1 conforming to UL 94
connections – terminals
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²rigid
Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²rigid
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end
Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable end
Control circuit: screw clamp terminals 1 cable(s) 1…2.5 mm²flexible with cable end
Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end
Power circuit: screw terminals 1 cable(s) 2.5…25 mm²rigid
Power circuit: screw terminals 2 cable(s) 2.5…16 mm²rigid
Power circuit: screw terminals 1 cable(s) 2.5…25 mm²flexible without cable end
Power circuit: screw terminals 2 cable(s) 2.5…16 mm²flexible without cable end
Power circuit: screw terminals 1 cable(s) 2.5…25 mm²flexible with cable end
Power circuit: screw terminals 2 cable(s) 2.5…10 mm²flexible with cable end
tightening torque
Control circuit: 1.2 N.m – on screw clamp terminal – with screwdriver flat Ø 6 mm
Control circuit: 1.2 N.m – on screw clamp terminal – with screwdriver Philips No 2
Power circuit: 5 N.m – on screw terminal – with screwdriver flat Ø 6 to Ø 8 mm
[Ue] rated operational voltage
Power circuit: <= 690 V AC 25…400 Hz
[Ith] conventional free air thermal current
10 A (at 60 °C) for control circuit
60 A (at 60 °C) for power circuit
Irms rated making capacity
250 A DC for control circuit conforming to IEC 60947-5-1
800 A at 440 V for power circuit conforming to IEC 60947
rated breaking capacity
800 A at 440 V for power circuit conforming to IEC 60947
associated fuse rating
10 A gG for control circuit conforming to IEC 60947-5-1
80 A gG at <= 690 V coordination type 1 for power circuit
80 A gG at <= 690 V coordination type 2 for power circuit
power dissipation per pole
5.4 W AC-1
2.4 W AC-3
inrush power in W
19 W (at 20 °C)
hold-in power consumption in W
7.4 W at 20 °C
operating time
20 ms opening
50 ms closing
safety reliability level
B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
mechanical durability
10000000 cycles
maximum operating rate
3600 cyc/h 60 °C
minimum switching current
5 mA for control circuit
minimum switching voltage
17 V for control circuit
non-overlap time
1.5 ms on de-energisation between NC and NO contacts
1.5 ms on energisation between NC and NO contacts
insulation resistance
> 10 MOhm for control circuit
rated operational power in W
14 W at 24 V DC-13 – electrical durability: 10000000 cycles – for control circuit
48 W at 24 V DC-13 – electrical durability: 3000000 cycles – for control circuit
96 W at 24 V DC-13 – electrical durability: 1000000 cycles – for control circuit
height
127 mm
width
85 mm
depth
176 mm
net weight
2.185 kg
compatibility code
LC1D