range |
TeSys
|
|
---|---|---|
product name |
TeSys D
|
|
product or component type |
Contactor
|
|
device short name |
LC1D
|
|
contactor application |
Resistive load
|
|
utilisation category |
AC-1
|
|
poles description |
4P
|
|
power pole contact composition |
4 NO
|
|
[Ue] rated operational voltage |
Power circuit: <= 300 V DC 25…400 Hz
Power circuit: <= 690 V AC |
|
[Ie] rated operational current |
125 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
|
|
control circuit type |
AC at 50/60 Hz
|
|
[Uc] control circuit voltage |
220 V AC 50/60 Hz
|
|
[Uimp] rated impulse withstand voltage |
8 kV conforming to IEC 60947
|
|
overvoltage category |
III
|
|
[Ith] conventional free air thermal current |
125 A (at 60 °C) for power circuit
|
|
Irms rated making capacity |
1100 A at 440 V for power circuit conforming to IEC 60947
|
|
rated breaking capacity |
1100 A at 440 V for power circuit conforming to IEC 60947
|
|
[Icw] rated short-time withstand current |
640 A 40 °C – 10 s for power circuit
990 A 40 °C – 1 s for power circuit 135 A 40 °C – 10 min for power circuit 320 A 40 °C – 1 min for power circuit |
|
associated fuse rating |
200 A gG at <= 690 V coordination type 1 for power circuit
160 A gG at <= 690 V coordination type 2 for power circuit |
|
average impedance |
0.8 mOhm – Ith 125 A 50 Hz for power circuit
|
|
[Ui] rated insulation voltage |
Power circuit: 600 V CSA certified
Power circuit: 600 V UL certified Power circuit: 1000 V conforming to IEC 60947-4-1 |
|
electrical durability |
0.8 Mcycles 125 A AC-1 at Ue <= 440 V
|
|
power dissipation per pole |
12.5 W AC-1
|
|
Front cover |
Without
|
|
mounting support |
Rail
Plate |
|
standards |
CSA C22.2 No 14
EN 60947-4-1 EN 60947-5-1 IEC 60947-4-1 IEC 60947-5-1 UL 508 |
|
product certifications |
DNV
LROS (Lloyds register of shipping) GL CSA CCC RINA UL GOST BV |
|
connections – terminals |
Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end
Control circuit: screw clamp terminals 1 cable(s) 1…2.5 mm²flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²solid without cable end Power circuit: connector 1 cable(s) 4…50 mm²flexible without cable end Power circuit: connector 2 cable(s) 4…25 mm²flexible without cable end Power circuit: connector 1 cable(s) 4…50 mm²flexible with cable end Power circuit: connector 2 cable(s) 4…16 mm²flexible with cable end Power circuit: connector 1 cable(s) 4…50 mm²solid without cable end Power circuit: connector 2 cable(s) 4…25 mm²solid without cable end |
|
tightening torque |
Control circuit: 1.2 N.m – on screw clamp terminals – with screwdriver flat Ø 6 mm
Control circuit: 1.2 N.m – on screw clamp terminals – with screwdriver Philips No 2 Power circuit: 12 N.m – on connector – with screwdriver flat Ø 6 to Ø 8 mm Power circuit: 12 N.m – on connector hexagonal screw head 4 mm |
|
operating time |
20…35 ms closing
6…20 ms opening |
|
safety reliability level |
B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 |
|
mechanical durability |
4 Mcycles
|
|
maximum operating rate |
3600 cyc/h 60 °C
|
coil technology |
Without built-in suppressor module
|
|
---|---|---|
control circuit voltage limits |
0.85…1.1 Uc (-40…55 °C):operational AC 60 Hz
0.3…0.6 Uc (-40…70 °C):drop-out AC 50/60 Hz 0.8…1.1 Uc (-40…55 °C):operational AC 50 Hz 1…1.1 Uc (55…70 °C):operational AC 50/60 Hz |
|
inrush power in VA |
245 VA 60 Hz cos phi 0.75 (at 20 °C)
245 VA 50 Hz cos phi 0.75 (at 20 °C) |
|
hold-in power consumption in VA |
26 VA 60 Hz cos phi 0.3 (at 20 °C)
26 VA 50 Hz cos phi 0.3 (at 20 °C) |
|
heat dissipation |
6…10 W at 50/60 Hz
|
|
contact compatibility |
M1
|
|
compatibility code |
LC1D
|
Reviews
There are no reviews yet.