LC1F3304M7 TeSys F contactor – 4P (4 NO) – AC-1 – <= 440 V 400 A - coil 220 V AC

Original price was: ₦1,944,920.00.Current price is: ₦1,137,551.42. 7.5% VAT

TeSys F contactor – 4P (4 NO) – AC-1 – <= 440 V 400 A – coil 220 V AC

SKU: LC1F3304M7 Category:
Main
range
TeSys
product name
TeSys F
product or component type
Contactor
device short name
LC1F
contactor application
Resistive load
utilisation category
AC-1
poles description
4P
power pole contact composition
4 NO
[Ue] rated operational voltage
<= 1000 V AC 50/60 Hz
<= 460 V DC
[Ie] rated operational current
400 A (at <40 °C) at <= 440 V AC AC-1
[Uc] control circuit voltage
220 V AC 40…400 Hz
Complementary
[Uimp] rated impulse withstand voltage
8 kV
overvoltage category
III
[Ith] conventional free air thermal current
400 A (at 40 °C)
rated breaking capacity
2640 A conforming to IEC 60947-4-1
[Icw] rated short-time withstand current
2650 A 40 °C – 10 s
1800 A 40 °C – 30 s
1300 A 40 °C – 1 min
900 A 40 °C – 3 min
750 A 40 °C – 10 min
associated fuse rating
400 A aM at <= 440 V
500 A gG at <= 440 V
average impedance
0.28 mOhm – Ith 400 A 50 Hz
[Ui] rated insulation voltage
1000 V conforming to IEC 60947-4-1
1500 V conforming to VDE 0110 group C
power dissipation per pole
44 W AC-1
mounting support
Plate
standards
JIS C8201-4-1
EN 60947-4-1
EN 60947-1
IEC 60947-4-1
IEC 60947-1
product certifications
LROS (Lloyds register of shipping)
DNV
RINA
BV
RMRoS
ABS
CB
UL
CCC
connections – terminals
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible without cable end
Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²flexible without cable end
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²flexible with cable end
Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm²flexible with cable end
Control circuit: screw clamp terminals 1 cable(s) 1…4 mm²solid without cable end
Control circuit: screw clamp terminals 2 cable(s) 1…4 mm²solid without cable end
Power circuit: lugs-ring terminals 1 cable(s) 240 mm²
Power circuit: bar 2 cable(s) – busbar cross section: 30 x 5 mm
Power circuit: bolted connection
tightening torque
Control circuit: 1.2 N.m
Power circuit: 35 N.m
control circuit voltage limits
Operational: 0.85…1.1 Uc 40…400 Hz (at 55 °C)
Drop-out: 0.35…0.55 Uc 40…400 Hz (at 55 °C)
inrush power in VA
650 VA 40…400 Hz cos phi 0.9 (at 20 °C)
hold-in power consumption in VA
10 VA 40…400 Hz cos phi 0.9 (at 20 °C)
heat dissipation
8 W
operating time
40…65 ms closing
100…170 ms opening
mechanical durability
10 Mcycles
maximum operating rate
2400 cyc/h 55 °C
compatibility code
LC1F