range of product |
Zelio Control
|
|
---|---|---|
product or component type |
Modular measurement and control relays
|
|
relay type |
Control relay
|
|
network number of phases |
3 phases
|
|
relay name |
RM22TR
|
|
relay monitored parameters |
Overvoltage and undervoltage detection
Phase sequence Phase failure detection |
|
time delay type |
Adjustable 0.1…30 s, +/- 10 % of the full scale value on crossing the threshold Tt
|
|
switching capacity in VA |
2000 VA
|
|
measurement range |
380…480 V voltage AC
|
reset time |
1500 ms at maximum voltage
|
|
---|---|---|
maximum switching voltage |
250 V AC
|
|
minimum switching current |
10 mA at 5 V DC
|
|
maximum switching current |
8 A AC
|
|
[Us] rated supply voltage |
380…480 V AC
|
|
supply voltage limits |
304…576 V AC
|
|
operating limits |
– 20 % + 20 % Un
|
|
power consumption in VA |
15 VA at 480 V AC 60 Hz
|
|
voltage detection threshold |
< 100 V AC
|
|
supply voltage frequency |
50…60 Hz +/- 10 %
|
|
output contacts |
2 C/O
|
|
nominal output current |
8 A
|
|
setting accuracy of the switching threshold |
+/- 10 % of the full scale
|
|
switching threshold drift |
<= 0.05 % per degree centigrade depending permissible ambient air temperature
<= 1 % within the supply voltage range |
|
setting accuracy of time delay |
10 P
|
|
time delay drift |
<= 0.05 % per degree centigrade depending permissible ambient air temperature
<= 1 % within the supply voltage range |
|
hysteresis |
2 % fixed of selectable
|
|
run-up delay at power-up |
650 ms
|
|
maximum measuring cycle |
150 ms measurement cycle as true rms value
|
|
threshold adjustment voltage |
2…20 % of Un selected
|
|
voltage range |
380…480 V phase to phase
|
|
repeat accuracy |
+/- 0.5 % for input and measurement circuit
+/- 3 % for time delay |
|
measurement error |
< 1 % over the whole range with voltage variation
< 0.05 %/°C with temperature variation |
|
response time |
<= 300 ms
|
|
overvoltage category |
III conforming to IEC 60664-1
III conforming to UL 508 |
|
insulation resistance |
> 100 MOhm at 500 V DC conforming to IEC 60255-27
|
|
mounting position |
Any position
|
|
connections – terminals |
Screw terminals, 2 x 0.5…2 x 2.5 mm² (AWG 20…AWG 14) solid without cable end
Screw terminals, 2 x 0.2…2 x 1.5 mm² (AWG 24…AWG 16) flexible with cable end Screw terminals, 1 x 0.5…1 x 3.3 mm² (AWG 20…AWG 12) solid without cable end Screw terminals, 1 x 0.2…1 x 2.5 mm² (AWG 24…AWG 14) flexible with cable end |
|
tightening torque |
0.6…1 N.m conforming to IEC 60947-1
|
|
housing material |
Self-extinguishing plastic
|
|
status LED |
LED (yellow)relay ON
LED (green)power ON |
|
mounting support |
35 mm DIN rail conforming to EN/IEC 60715
|
|
electrical durability |
100000 cycles
|
|
mechanical durability |
10000000 cycles
|
|
utilisation category |
AC-15 conforming to IEC 60947-5-1
DC-13 conforming to IEC 60947-5-1 AC-1 conforming to IEC 60947-4-1 DC-1 conforming to IEC 60947-4-1 |
|
safety reliability data |
MTTFd = 388.1 years
B10d = 350000 |
|
contacts material |
Cadmium free
|
|
width |
22.5 mm
|
|
net weight |
0.09 kg
|