Sale!

SK827044-AL EK1000-40-11 220-230V 50Hz / 240V 60Hz Contactor

Original price was: ₦1,145,035.00.Current price is: ₦1,135,035.00. 7.5% VAT

EK1000-40-11 220-230V 50Hz / 240V 60Hz Contactor

SKU: SK827044-AL Category:

General Information

  • Extended Product Type:
    EK1000-40-11 220-230V 50Hz / 240V 60Hz
  • Product ID:
    SK827044-AL
  • EAN:
    7320500194249
  • Catalog Description:
    EK1000-40-11 220-230V 50Hz / 240V 60Hz Contactor
  • Long Description:
    A 4-pole Contactor suitable for Distribution and Rail way applications AC and DC switching. Operated with control voltage, versions from 24….690 AC, 50/60 Hz and 24-220 V DC

Categories

  • Products » Low Voltage Products and Systems » Control Products » Contactors » Block Contactors

Technical

  • Number of Main Contacts NO:
    4
  • Number of Main Contacts NC:
    0
  • Number of Auxiliary Contacts NO:
    1
  • Number of Auxiliary Contacts NC:
    1
  • Rated Operational Voltage:
    Main Circuit 1000 V
  • Conventional Free-air Thermal Current (Ith):
    acc. to IEC 60947-4-1, Open Contactors q = 40 °C 1000 A
  • Rated Operational Current AC-1 (Ie):
    (1000 V) 40 °C 1000 A
    (1000 V) 60 °C 800 A
    (1000 V) 70 °C 720 A
    (690 V) 40 °C 1000
    (690 V) 55 °C 800
    (690 V) 60 °C 800 A
    (690 V) 70 °C 720
  • Rated Short-time Withstand Current (Icw):
    at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 6400 A
    at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 1200 A
    at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 3400 A
    at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 6800 A
    at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 4400 A
  • Maximum Electrical Switching Frequency:
    (AC-1) 300 cycles per hour
  • Rated Insulation Voltage (Ui):
    acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
    acc. to UL/CSA 600 V
  • Rated Impulse Withstand Voltage (Uimp):
    8 kV
  • Mechanical Durability:
    5 million
  • Maximum Mechanical Switching Frequency:
    3600 cycles per hour
  • Coil Operating Limits:
    (acc. to IEC 60947-4-1) Uc (at θ ≤ 70 °C)
  • Rated Control Circuit Voltage (Uc):
    50 Hz 220 … 230 V
    60 Hz 240 V
  • Coil Consumption:
    Holding at Max. Rated Control Circuit Voltage 50 Hz 125 V·A
    Holding at Max. Rated Control Circuit Voltage 60 Hz 140 V·A
    Pull-in at Max. Rated Control Circuit Voltage 50 Hz 3500 V·A
    Pull-in at Max. Rated Control Circuit Voltage 60 Hz 4000 V·A
  • Operate Time:
    Between Coil De-energization and NC Contact Closing 10 … 20 ms
    Between Coil De-energization and NO Contact Opening 13 … 23 ms
    Between Coil Energization and NC Contact Opening 25 … 55 ms
    Between Coil Energization and NO Contact Closing 30 … 60 ms
  • Degree of Protection:
    acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
  • Connecting Terminals (delivered in open position) Main Poles:
    Flat type c/w screws and bolts
  • Terminal Type:
    Main Circuit: Bars