Quanta BATTERY – 26 AH

Amaron Quanta BATTERY – 26 AH

These batteries are manfucatured at world class facilities in assoication with Johnson Controls. Amaron Quanta Batteries are a product of world class battery technology produced and tested in Amara Raja’s premier VRLA manufacturing facility, supported by technology expertise from alliance partner Johnson Control Inc. A market leader in just 10 years, Amaron Quanta is a preferred 12V VRLA SMF battery brand by most of reputed UPS manufacturers and customers across various segments like Banks, IT Companies, BPOs, Industries, Government Departments, Hospital, and Education Institutes etc.
The unique benefits Amaron Quanta Offers to its customers are:

  • HIGHER LIFE : Patented heavy duty lead alloy gives higher service Life
  • HIGHER POWER : Unique “Rugged” profile, ensuring more power for the same AH
  • FASTER RECHARGE : Patented “Instacharge”, paste recipe for excellent charge acceptance
  • HIGHLY RELIABLE : Comes out of Amara Raja’s world class manufacturing facility
  • AFTER SALES SUPPORT : Prompt after sales support across Nigeria
Category:

Specification

Nominal voltage 12 Volts
Rated capacity (C20 Hour rate at 27°C) 26 Ampere Hour
Dimensions (±2 mm) Length 167 mm
Width 126 mm
Height 175 mm
Weight ± 1.0 Kgs (approx.) 9.0 Kgs

Characteristics

Capacity@ 80.6°F (27°C) 20 hour rate (1.30A) upto 10.5V 26.0 Ah
10 hour rate (2.42A) upto 10.5V 24.20 Ah
5 hour rate (4.46A) upto 10.2V 22.30 Ah
1 hour rate (16.88A) upto 9.6V 16.88 Ah
15 minute rate (46.93A) upto 9.6V 11.73 Ah
Internal resistance Fully charged battery 80.6°F (27°C) 9.80 mQ
Capacity affected (Temperature at C20 hour rate) 104° F (40°C) 110%
80.6°F (27°C) 100%
32°F(0°C) 80%
5°F (-15°C) 60%
Self discharge 80.6°F (27°C) Capacity after 3 month storage 90%
Capacity after 6 month storage 80%
Terminal Type M5 x 20 mm Bolted
Short circuit current 1278 A

Constant power discharge rating watts per battery @ 27°C *

DURATION
ECV 10 min 15 min 20 min 30 min 60 min 2 hrs 3 hrs 5 hrs 8 hrs 10 hrs 20 hrs
1.60 716 557 456 340 211 120 82.0 56.0 36.0 31.0 15.0
1.65 712 548 448 330 207 119 81.0 55.0 35.5 30.5 14.5
1.70 707 538 440 320 202 118 80.0 54.0 35.0 30.0 14.0
1.75 673 518 424 311 198 117 79.5 53.5 34.5 29.5 13.5
1.80 638 498 408 302 193 116 79.0 53.0 34.0 29.0 13.0

Constant current discharge rating amperes @ 27 °C *

DURATION
ECV 10 min 15 min 20 min 30 min 60 min 2 hr 3 hr 5 hr 8 hr 10 hr 20 hr
1.60 58.72 46.93 37.25 28.26 16.88 10.24 7.00 4.82 2.99 2.53 1.39
1.65 56.93 44.92 35.89 27.13 16.67 9.83 6.79 4.64 2.92 2.50 1.36
1.70 55.14 42.90 34.53 26.00 16.46 9.41 6.58 4.46 2.86 2.47 1.32
1.75 53.06 41.94 34.21 25.74 16.25 9.29 6.57 4.44 2.84 2.42 1.30
1.80 52.00 41.27 33.33 25.49 15.55 9.22 6.53 4.41 2.83 2.41 1.29