General Information
-
- Extended Product Type:
- PST44-600-70
-
- Product ID:
- 1SFA894004R7000
-
- EAN:
- 7320500255520
-
- Catalog Description:
- PST44-600-70 SOFTSTARTER
-
- Long Description:
- Softstarter PST44-600-70 for max 600V main voltage and 110 – 240V 50/60Hz control supply voltage
Categories
- Products » Drives » Softstarters » Softstarters » PST(B) Softstarters » PST44
- Products » Low Voltage Products and Systems » Control Products » Softstarters » Softstarters » PST(B) Softstarters » PST44
Dimensions
-
- Product Net Width:
- 160.000 mm
-
- Product Net Height:
- 260.000 mm
-
- Product Net Depth / Length:
- 196.000 mm
-
- Product Net Weight:
- 4.8 kg
Technical
-
- Rated Operational Voltage:
- Main Circuit 208 … 600 V AC
-
- Rated Control Supply Voltage (Us):
- 100 … 250 V AC
-
- Rated Control Circuit Voltage (Uc):
- DC Operation 24 V
-
- Rated Frequency (f):
- Main Circuit 50/60 Hz
Control Supply 50/60 Hz
-
- Rated Operational Power – In-Line Connection (Pe):
- (400 V) 22 kW
(500 V) 25 kW
-
- Rated Operational Current – In-Line Connection (Ie):
- 44 A
-
- Rated Operational Power – Inside Delta Connection:
- at 400 V 37 kW
at 500 V 45 kW
-
- Rated Operational Current – Inside Delta Connection:
- 76 A
-
- Service Factor Percentage:
- 115 %
-
- Overload Protection:
- Build-in electronic overload protection
-
- Integrated Electronic Overload:
- Yes
-
- Adjustable Rated Motor Current Ie:
- 30 … 115 %
-
- Starting Capacity at Maximum Rated Current Ie:
- 3xIe for 15s
-
- Ramp Time:
- During Start 1 … 30 second [unit of time]
During Start 1 … 120 second [unit of time]
During Stop 0 … 30 second [unit of time]
During Stop 0 … 120 second [unit of time]
-
- Initial Voltage During Start:
- 30 … 70 %
-
- Step Down Voltage Special Ramp:
- 100 … 30 %
-
- Current Limit Function:
- 1.5 … 7xIe
-
- Switch for Inside Delta Connection:
- Yes
-
- Run Signal Relay:
- Yes
-
- By-pass Signal Relay:
- Yes
-
- Fault Signal Relay:
- Yes
-
- Overload Signal Relay:
- Yes
-
- Analog Outputs:
- 0…10 volts
0…20 mA
4…20 mA
-
- Signal indication ready to start/standby ON (LED):
- Green
-
- Signal indication protection (LED):
- Yellow
-
- Signal indication fault (LED):
- Red
-
- Number of Starts Per Hour at 3.5*Ie for 7 sec. 50% ON Time 50% OFF Time:
- 30
-
- Communication:
- FiledBusPlug(Standard)
-
- Degree of Protection:
- acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
-
- Terminal Type:
- Screw Terminals
-
- Connecting Capacity Main Circuit:
- Rigid 1 x 10 … 95 mm²
Rigid 2 x 6 … 35 mm²
-
- Connecting Capacity Control Circuit:
- Rigid 1×2.5 mm²
Rigid 2×1.5 mm²
-
- Connecting Capacity Supply Circuit:
- Rigid 1×2.5 mm²
Rigid 2×1.5 mm²
-
- Tightening Torque:
- Main Circuit 6 N·m
Supply Circuit 0.5 N·m
Control Circuit 0.5 N·m
-
- Product Main Type:
- PST44