Sale!

1SBL241022R8410 UA26-30-10 110V 50Hz / 110-120V 60Hz Contactor

28,375.00 7.5% VAT

UA26-30-10 110V 50Hz / 110-120V 60Hz Contactor

SKU: 1SBL241022R8410 Category:

General Information

  • Extended Product Type:
    UA26-30-10 110V 50Hz / 110-120V 60Hz
  • Product ID:
    1SBL241022R8410
  • EAN:
    3471522069849
  • Catalog Description:
    UA26-30-10 110V 50Hz / 110-120V 60Hz Contactor
  • Long Description:
    UA26 3-pole contactors for capacitor switching, can be used for the switching of capacitor banks whose inrush current peaks are less than or equal to 100 times nominal rms current. The table below gives the permissible powers according to operational voltage and temperature close to the contactor. It also specifies the maximum peak current Î values accepted by the contactor. The capacitors must be discharged (maximum residual voltage at terminals ≤ 50 V) before being re-energized when the contactors are making. In these conditions, electrical durability of contactors is equal to 100 000 operating cycles. The UA.. series 3-pole contactors are of the block type design. – Main poles and auxiliary contacts: 3 main poles, 1 built-in auxiliary contact – Control circuit: AC operated with laminated magnet circuit – Accessories: a wide range of accessories is available.

Categories

  • Products » Low Voltage Products and Systems » Control Products » Contactors » Contactors » UA and UA..RA Contactors

Technical

  • Number of Main Contacts NO:
    3
  • Number of Main Contacts NC:
    0
  • Number of Auxiliary Contacts NO:
    1
  • Number of Auxiliary Contacts NC:
    0
  • Rated Operational Voltage:
    Auxiliary Circuit 690 V
    Main Circuit 690 V
  • Rated Frequency (f):
    Supply Circuit 50 60 Hz
  • Conventional Free-air Thermal Current (Ith):
    acc. to IEC 60947-5-1, q = 40 °C 16 A
  • Rated Operational Power AC-6b (Pe):
    (230 / 240 V) 40 °C, 50 / 60 Hz 12 kvar
    (230 / 240 V) 55 °C, 50 / 60 Hz 11 kvar
    (230 / 240 V) 70 °C, 50 / 60 Hz 8.5 kvar
    (400 / 415 V) 40 °C, 50 / 60 Hz 20 kvar
    (400 / 415 V) 70 °C, 50 / 60 Hz 14.5 kvar
    (400 / 415 V) 55 °C, 50 / 60 Hz 18.5 kvar
    (440 V) 40 °C, 50 / 60 Hz 22 kvar
    (440 V) 55 °C, 50 / 60 Hz 20 kvar
    (440 V) 70 °C, 50 / 60 Hz 16 kvar
    (500 / 550 V), 40 °C, 50 / 60 Hz 22 kvar
    (500 / 550 V) 55 °C, 50 / 60 Hz 22 kvar
    (500 / 550 V) 70 °C, 50 / 60 Hz 19.5 kvar
    (690 V) 40 °C, 50 / 60 Hz 30 kvar
    (690 V) 55 °C, 50 / 60 Hz 30 kvar
    (690 V) 70 °C, 50 / 60 Hz 25 kvar
  • Rated Operational Current AC-15 (Ie):
    (500 V) 2 A
    (690 V) 2 A
    (24 / 127 V) 6 A
    (220 / 240 V) 4 A
    (380 / 400 V) 3 A
  • Short-Circuit Protective Devices:
    Auxiliary Circuit – gG Type Fuses 10 A
    gG Type Fuses 1.5 … 1.8 A
  • Maximum Breaking Capacity:
    cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 420 A
    cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 170 A
  • Rated Operational Current DC-13 (Ie):
    (24 V) 6 / 144 A
    (48 V) 2.8 / 134 A
    (72 V) 2 / 144 A
    (125 V) 1.1 / 138 A
    (250 V) 0.55 / 138 A
  • Rated Insulation Voltage (Ui):
    acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
    acc. to UL/CSA 600 V
  • Rated Impulse Withstand Voltage (Uimp):
    8 kV
  • Maximum Mechanical Switching Frequency:
    3600 cycles per hour
  • Rated Control Circuit Voltage (Uc):
    50 Hz 110 V
    60 Hz 110 … 120 V
  • Coil Consumption:
    Average Holding Value 50 / 60 Hz 12 3 V·A
    Average Pull-in Value 50 Hz 120 V·A
    Average Pull-in Value 60 Hz 120 V·A
    Holding at Max. Rated Control Circuit Voltage 50 Hz 12 3 V·A
    Holding at Max. Rated Control Circuit Voltage 60 Hz 12 3 V·A
    Pull-in at Max. Rated Control Circuit Voltage 50 Hz 120 V·A
    Pull-in at Max. Rated Control Circuit Voltage 60 Hz 140 V·A
  • Operate Time:
    Between Coil De-energization and NO Contact Opening 4 … 11 ms
    Between Coil Energization and NO Contact Closing 8 … 21 ms
  • Connecting Capacity Main Circuit:
    Flexible with Cable End 0.75 … 4 mm²
    Rigid Cable 1.5 … 6 mm²
  • Connecting Capacity Auxiliary Circuit:
    Flexible with Cable End 0.75 … 2.5 mm²
    Rigid Cable 1 … 4 mm²
  • Degree of Protection:
    acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
  • Connecting Terminals (delivered in open position) Main Poles:
    M 4 (+,-) pozidriv 2 screws with cable clamp
  • Terminal Type:
    Screw Terminals

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.