General Information
-
- Extended Product Type:
- AX32-30-10-80
-
- Product ID:
- 1SBL281074R8010
-
- EAN:
- 3471522399809
-
- Catalog Description:
- AX32-30-10-80 220-230V50Hz/230-240V60Hz Contactor
-
- Long Description:
- AX32, AX40 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC. These contactors are of the block type design with: – 3 main poles and 1 built-in auxiliary contact – control circuit: AC operated – add-on auxiliary contact blocks for front or side mounting and a wide range of accessories.
Categories
- Products » Low Voltage Products and Systems » Control Products » Contactors » Block Contactors
Technical
-
- Number of Main Contacts NO:
- 3
-
- Number of Main Contacts NC:
- 0
-
- Number of Auxiliary Contacts NO:
- 1
-
- Number of Auxiliary Contacts NC:
- 0
-
- Rated Operational Voltage:
- Auxiliary Circuit 690 V
Main Circuit 690 V
-
- Rated Frequency (f):
- Auxiliary Circuit 50 / 60 Hz
Main Circuit 50 / 60 Hz
-
- Conventional Free-air Thermal Current (Ith):
- acc. to IEC 60947-4-1, Open Contactors q = 40 °C 65 A
acc. to IEC 60947-5-1, q = 40 °C 16 A
-
- Rated Operational Current AC-1 (Ie):
- (690 V) 40 °C 55 A
(690 V) 70 °C 39 A
(220 / 240 V) 55 °C 55 A
-
- Rated Operational Current AC-3 (Ie):
- (220 / 230 / 240 V) 55 °C 32 A
(380 / 400 V) 55 °C 32 A
(415 V) 55 °C 32 A
(440 V) 55 °C 32 A
(500 V) 55 °C 28 A
(690 V) 55 °C 21 A
-
- Rated Operational Power AC-3 (Pe):
- (220 / 230 / 240 V) 9 kW
(380 / 400 V) 15 kW
(415 V) 15 kW
(440 V) 18.5 kW
(500 V) 18.5 kW
(690 V) 18.5 kW
-
- Rated Operational Current AC-15 (Ie):
- (220 / 240 V) 4 A
(24 / 127 V) 6 A
(400 / 440 V) 2 A
(500 V) 2 A
(690 V) 2 A
(380 / 440 V) 3 A
-
- Rated Short-time Withstand Current (Icw):
- at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 400 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 65 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 150 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 600 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 225 A
for 0.1 s 140 A
for 1 s 100 A
-
- Maximum Breaking Capacity:
- cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 820 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 340 A
-
- Maximum Electrical Switching Frequency:
- (AC-1) 600 cycles per hour
(AC-15) 1200 cycles per hour
(AC-3) 1200 cycles per hour
(DC-13) 900 cycles per hour
-
- Rated Operational Current DC-13 (Ie):
- (110 V) 1.1 A / 121 W
(220 V) 0.55 A / 121 W
(400 V) 2.8 A / 134 W
(500 V) 2 A / 144 W
(125 V) 1.1 A / 138 W
(24 V) 6 A / 144 W
(250 V) 0.55 A / 138 W
-
- Rated Insulation Voltage (Ui):
- acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
-
- Rated Impulse Withstand Voltage (Uimp):
- 6 kV
-
- Maximum Mechanical Switching Frequency:
- 3600 cycles per hour
-
- Rated Control Circuit Voltage (Uc):
- 50 Hz 220 … 230 V
60 Hz 230 … 240 V
-
- Operate Time:
- Between Coil De-energization and NC Contact Closing 7 … 14 ms
Between Coil De-energization and NO Contact Opening 4 … 11 ms
Between Coil Energization and NC Contact Opening 6 … 18 ms
Between Coil Energization and NO Contact Closing 8 … 21 ms
-
- Degree of Protection:
- acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
-
- Terminal Type:
- Screw Terminals
Technical UL/CSA
-
- General Use Rating UL/CSA:
- (600 V AC) 50 A
-
- Horsepower Rating UL/CSA:
- (120 V AC) Single Phase 3 Hp
(240 V AC) Single Phase 7.5 Hp
(200 … 208 V AC) Three Phase 10 Hp
(220 … 240 V AC) Three Phase 10 Hp
(440 … 480 V AC) Three Phase 25 Hp
(550 … 600 V AC) Three Phase 30 Hp
-
- Tightening Torque UL/CSA:
- Auxiliary Circuit 9 in·lb
Control Circuit 9 in·lb
Main Circuit 20 in·lb