General Information
-
- Extended Product Type:
- AX80-30-11-80
-
- Product ID:
- 1SBL411074R8011
-
- EAN:
- 3471522408808
-
- Catalog Description:
- AX80-30-11-80 220-230V50Hz/230-240V60Hz Contactor
-
- Long Description:
- AX50…AX80 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC. These contactors are of the block type design with: – 3 main poles – control circuit: AC operated – add-on auxiliary contact blocks (optional) for side mounting and a wide range of accessories.
Categories
- Products » Low Voltage Products and Systems » Control Products » Contactors » Block Contactors
Technical
-
- Number of Main Contacts NO:
- 3
-
- Number of Main Contacts NC:
- 0
-
- Number of Auxiliary Contacts NO:
- 1
-
- Number of Auxiliary Contacts NC:
- 1
-
- Rated Operational Voltage:
- Auxiliary Circuit 690 V
Main Circuit 690 V
-
- Rated Frequency (f):
- Auxiliary Circuit 50 / 60 Hz
Main Circuit 50 / 60 Hz
-
- Conventional Free-air Thermal Current (Ith):
- acc. to IEC 60947-4-1, Open Contactors q = 40 °C 125 A
-
- Rated Operational Current AC-1 (Ie):
- (690 V) 40 °C 125 A
(690 V) 70 °C 85 A
(220 / 240 V) 55 °C 105 A
-
- Rated Operational Current AC-3 (Ie):
- (220 / 230 / 240 V) 55 °C 80 A
(380 / 400 V) 55 °C 80 A
(415 V) 55 °C 80 A
(440 V) 55 °C 70 A
(500 V) 55 °C 65 A
(690 V) 55 °C 46 A
-
- Rated Operational Power AC-3 (Pe):
- (220 / 230 / 240 V) 22 kW
(380 / 400 V) 37 kW
(415 V) 40 kW
(440 V) 40 kW
(500 V) 45 kW
(690 V) 40 kW
-
- Rated Short-time Withstand Current (Icw):
- at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 650 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 135 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1000 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 370 A
for 1 s -empty- A
-
- Maximum Breaking Capacity:
- cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1300 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 630 A
-
- Maximum Electrical Switching Frequency:
- (AC-1) 600 cycles per hour
(AC-3) 600 cycles per hour
-
- Rated Insulation Voltage (Ui):
- acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
-
- Rated Impulse Withstand Voltage (Uimp):
- 6 kV
-
- Maximum Mechanical Switching Frequency:
- 3600 cycles per hour
-
- Rated Control Circuit Voltage (Uc):
- 50 Hz 220 … 230 V
60 Hz 230 … 240 V
-
- Operate Time:
- Between Coil De-energization and NC Contact Closing 7 … 14 ms
Between Coil De-energization and NO Contact Opening 4 … 11 ms
Between Coil Energization and NC Contact Opening 7 … 22 ms
Between Coil Energization and NO Contact Closing 8 … 27 ms
-
- Degree of Protection:
- acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
-
- Terminal Type:
- Screw Terminals
Technical UL/CSA
-
- General Use Rating UL/CSA:
- (600 V AC) 105 A
-
- Horsepower Rating UL/CSA:
- (120 V AC) Single Phase 7-1/2 Hp
(240 V AC) Single Phase 15 Hp
(200 … 208 V AC) Three Phase 25 Hp
(220 … 240 V AC) Three Phase 30 Hp
(440 … 480 V AC) Three Phase 60 Hp
(550 … 600 V AC) Three Phase 75 Hp
-
- Tightening Torque UL/CSA:
- Auxiliary Circuit 9 in·lb
Control Circuit 9 in·lb
Main Circuit 35 in·lb
Reviews
There are no reviews yet.