SKU: 56193 Category:
Main
range
Vigirex
range of product
Vigirex
device short name
RH99M
product or component type
Monitoring relay
Current sensors compatibility
TOA earth leakage current sensor
A earth leakage current sensor
L earth leakage current sensor
relay application
Monitoring relay
Complementary
Monitored distribution system
1000 V – AC at 50/60 Hz (maximum)
1000 V – AC at 400 Hz (maximum)
earthing system
TT
TN-S
[Us] rated supply voltage
220…240 V AC 50/60 Hz 70…110 %
power consumption in VA
4 VA
type of measurement
Earth fault current internal measurement, range: 80…100 %
threshold setting
0.03…30 A alarm
residual earth-leakage time delay adjustment type
Adjustable 9 settings 0.1…30 A 0…4.5 s
Instantaneous 0.03…30 A
test function
Local
Remote test
monitoring
Electronics (continuous)
Power supply (continuous)
Relay/sensor link (continuous)
[Ithe] conventional enclosed thermal current
8 A
minimum load
10 mA at 12 V
net weight
0.3 kg
IP degree of protection
IP40 on front face: conforming to EN/IEC 60529
IP30 on side parts: conforming to EN/IEC 60529
IP20 on connection terminals: conforming to EN/IEC 60529
IK degree of protection
IK07 conforming to EN 50102
mechanical robustness
Fire resistance conforming to IEC 60695-2-1
IK protection 2 joules: IK07 conforming to EN 50102
Vibrations 13.2…100 Hz: 0.7 g
Vibrations 2…13.2 Hz: +/- 1 mm
earth-leakage protection class
Class AC
Class A
overvoltage category
IV
tamperproof of settings
Protected by sealable cover
mounting support
DIN rail
height
81 mm
width
54 mm
depth
74 mm
9 mm pitches
6
connections – terminals
Auxiliary power supply: terminal block cable(s) 0.2…2.5 mm² flexible AWG 24…AWG 12
Auxiliary power supply: terminal block cable(s) 0.2…2.5 mm² rigid AWG 24…AWG 12
Auxiliary power supply: terminal block cable(s) 0.25…2.5 mm² flexible with ferrule AWG 24…AWG 12
Fault: screw terminal cable(s) 0.2…2.5 mm² flexible AWG 24…AWG 12
Fault: screw terminal cable(s) 0.2…4 mm² rigid AWG 24…AWG 12
Fault: screw terminal cable(s) 0.25…2.5 mm² flexible with ferrule AWG 24…AWG 12
Relay test and fault reset: screw terminal cable(s) 0.14…1 mm² flexible AWG 26…AWG 16
Relay test and fault reset: screw terminal cable(s) 0.14…1.5 mm² rigid AWG 26…AWG 16
Relay test and fault reset: screw terminal cable(s) 0.25…0.5 mm² flexible with ferrule AWG 26…AWG 16
Sensor: screw terminal cable(s) 0.14…1 mm² flexible AWG 26…AWG 16
Sensor: screw terminal cable(s) 0.14…1.5 mm² rigid AWG 26…AWG 16
Sensor: screw terminal cable(s) 0.25…0.5 mm² flexible with ferrule AWG 26…AWG 16
Voltage presence: screw terminal cable(s) 0.2…2.5 mm² flexible AWG 24…AWG 12
Voltage presence: screw terminal cable(s) 0.2…4 mm² rigid AWG 24…AWG 12
Voltage presence: screw terminal cable(s) 0.25…2.5 mm² flexible with ferrule AWG 24…AWG 12
wire stripping length
Auxiliary power supply: 7 mm for top connection
Fault: 8 mm for bottom connection
Relay test and fault reset: 5 mm for bottom connection
Sensor: 5 mm for top connection
Voltage presence: 8 mm for bottom connection
tightening torque
Auxiliary power supply: 0.6 N.m top
Fault: 0.6 N.m bottom
Relay test and fault reset: 0.25 N.m bottom
Sensor: 0.25 N.m top
Voltage presence: 0.6 N.m bottom