Sale!

ATS48C21Q Soft starter for asynchronous motor – ATS48 – 195 A – 230..415 V – 45..160 KW

967,555.00 7.5% VAT

Soft starter for asynchronous motor – ATS48 – 195 A – 230..415 V – 45..160 KW

SKU: ATS48C21Q Category:
Main
range of product
Altistart 48
product or component type
Soft starter
product destination
Asynchronous motors
product specific application
Heavy duty industry and pumps
device short name
ATS48
power supply voltage
230…415 V – 15…10 %
motor power kW
55 kW at 230 V connection in the motor supply line for standard applications
90 kW at 230 V connection to the motor delta terminals for severe applications
90 kW at 400 V connection in the motor supply line for severe applications
110 kW at 230 V connection to the motor delta terminals for standard applications
110 kW at 400 V connection in the motor supply line for standard applications
132 kW at 400 V connection to the motor delta terminals for severe applications
160 kW at 400 V connection to the motor delta terminals for standard applications
45 kW at 230 V connection in the motor supply line for severe applications
power dissipation in W
468 W for severe applications
580 W for standard applications
utilisation category
AC-53A
type of start
Start with torque control (current limited to 5 In)
Icl nominal current
210 A for connection in the motor supply line for severe applications
210 A for connection in the motor supply line for standard applications
364 A for connection to the motor delta terminals for severe applications
364 A for connection to the motor delta terminals for standard applications
IP degree of protection
IP00
Complementary
assembly style
With heat sink
function available
External bypass (optional)
power supply voltage limits
195…456 V
power supply frequency
50…60 Hz – 5…5 %
power supply frequency limits
47.5…63 Hz
device connection
To the motor delta terminals
In the motor supply line
factory setting current
195 A
[Uc] control circuit voltage
220 – 15 % to 415 + 10 %, 50/60 Hz
control circuit consumption
50 W
discrete output number
2
discrete output type
(LO1) logic output 0 V common configurable
(LO2) logic output 0 V common configurable
(R1) relay outputs fault relay NO
(R2) relay outputs end of starting relay NO
(R3) relay outputs motor powered NO
output absolute accuracy precision
+/- 5 %
minimum switching current
10 mA at 6 V DC for relay outputs
maximum switching current
Logic output 0.2 A at 30 V DC
Relay outputs 1.8 A at 230 V AC inductive load, cos phi = 0.5 20 ms
Relay outputs 1.8 A at 30 V DC inductive load, cos phi = 0.5 20 ms
discrete input number
5
discrete input type
PTC, 750 Ohm at 25 °C
(Stop, Run, LI3, LI4) logic, <= 8 mA 4300 Ohm
discrete input voltage
24 V <= 30 V
discrete input logic
Positive logic Stop, Run, LI3, LI4 at State 0: < 5 V and <= 2 mA at State 1: > 11 V, >= 5 mA
starting current
0.4…1.3 Icl adjustable
analogue output type
Current output AO: 0-20 mA or 4-20 mA, impedance <500 Ohm
communication port protocol
Modbus
connector type
1 RJ45
communication data link
Serial
physical interface
RS485 multidrop
transmission rate
4800, 9600 or 19200 bps
max nodes number
31
protection type
Phase failure: line
Thermal protection: motor
Thermal protection: starter
marking
CE
type of cooling
Forced convection
operating position
Vertical +/- 10 degree
height
380 mm
width
320 mm
depth
265 mm
net weight
18.2 kg
Motor power range AC-3
30…50 kW at 200…240 V 3 phases
55…100 kW at 380…440 V 3 phases
55…100 kW at 200…240 V 3 phases
110…220 kW at 380…440 V 3 phases
110…220 kW at 200…240 V 3 phases
motor starter type
Soft starter

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.