Sale!

ATS48M10Y Soft starter for asynchronous motor – ATS48 – 954 A – 208..690 V – 250..900 KW

5,696,290.00 7.5% VAT

Soft starter for asynchronous motor – ATS48 – 954 A – 208..690 V – 250..900 KW

SKU: ATS48M10Y Category:
Main
range of product
Altistart 48
product or component type
Soft starter
product destination
Asynchronous motors
product specific application
Heavy duty industry and pumps
device short name
ATS48
power supply voltage
208…690 V – 15…10 %
motor power kW
220 kW at 230 V for severe applications
250 kW at 230 V for standard applications
400 kW at 400 V for severe applications
500 kW at 400 V for standard applications
500 kW at 440 V for severe applications
500 kW at 500 V for severe applications
500 kW at 525 V for severe applications
630 kW at 440 V for standard applications
630 kW at 500 V for standard applications
630 kW at 525 V for standard applications
710 kW at 660 V for severe applications
710 kW at 690 V for severe applications
900 kW at 660 V for standard applications
900 kW at 690 V for standard applications
motor power hp
1000 hp at 575 V for standard applications
250 hp at 208 V for severe applications
300 hp at 230 V for severe applications
350 hp at 208 V for standard applications
350 hp at 230 V for standard applications
600 hp at 460 V for severe applications
800 hp at 460 V for standard applications
800 hp at 575 V for severe applications
power dissipation in W
2225 W for standard applications
2865 W for standard applications
utilisation category
AC-53A
type of start
Start with torque control (current limited to 5 In)
Icl nominal current
1000 A for connection in the motor supply line for standard applications
1000 A for connection in the motor supply line for severe applications
IP degree of protection
IP00
Complementary
assembly style
With heat sink
function available
External bypass (optional)
power supply voltage limits
177…759 V
power supply frequency
50…60 Hz – 5…5 %
power supply frequency limits
47.5…63 Hz
device connection
In the motor supply line
factory setting current
954 A
[Uc] control circuit voltage
110 – 15 % to 230 + 10 %, 50/60 Hz
control circuit consumption
80 W
discrete output number
2
discrete output type
(LO1) logic output 0 V common configurable
(LO2) logic output 0 V common configurable
(R1) relay outputs fault relay NO
(R2) relay outputs end of starting relay NO
(R3) relay outputs motor powered NO
output absolute accuracy precision
+/- 5 %
minimum switching current
10 mA at 6 V DC for relay outputs
maximum switching current
Logic output 0.2 A at 30 V DC
Relay outputs 1.8 A at 230 V AC inductive load, cos phi = 0.5 20 ms
Relay outputs 1.8 A at 30 V DC inductive load, cos phi = 0.5 20 ms
discrete input number
5
discrete input type
PTC, 750 Ohm at 25 °C
(Stop, Run, LI3, LI4) logic, <= 8 mA 4300 Ohm
discrete input voltage
24 V <= 30 V
discrete input logic
Positive logic Stop, Run, LI3, LI4 at State 0: < 5 V and <= 2 mA at State 1: > 11 V, >= 5 mA
starting current
0.4…1.3 Icl adjustable
analogue output type
Current output AO: 0-20 mA or 4-20 mA, impedance <500 Ohm
communication port protocol
Modbus
connector type
1 RJ45
communication data link
Serial
physical interface
RS485 multidrop
transmission rate
4800, 9600 or 19200 bps
max nodes number
31
protection type
Phase failure: line
Thermal protection: motor
Thermal protection: starter
marking
CE
type of cooling
Forced convection
operating position
Vertical +/- 10 degree
height
890 mm
width
770 mm
depth
315 mm
net weight
115 kg
Motor power range AC-3
110…220 kW at 200…240 V 3 phases
250…500 kW at 380…440 V 3 phases
250…500 kW at 480…500 V 3 phases
250…500 kW at 200…240 V 3 phases
560…900 kW at 380…440 V 3 phases
560…900 kW at 480…500 V 3 phases
motor starter type
Soft starter

Reviews

There are no reviews yet.