Main
range of product
Altivar Process ATV600
product or component type
Variable speed drive
product specific application
Process and utilities
device short name
ATV630
variant
Standard version
product destination
Asynchronous motors
Synchronous motors
EMC filter
Integrated with 50 m conforming to EN/IEC 61800-3 category C2
Integrated with 150 m conforming to EN/IEC 61800-3 category C3
IP degree of protection
IP21 conforming to IEC 61800-5-1
IP21 conforming to IEC 60529
degree of protection
UL type 1 conforming to UL 508C
type of cooling
Forced convection
supply frequency
50…60 Hz – 5…5 %
network number of phases
3 phases
[Us] rated supply voltage
380…480 V – 15…10 %
motor power kW
4 kW (normal duty)
3 kW (heavy duty)
motor power hp
5 hp normal duty
4 hp heavy duty
line current
7.6 A at 380 V (normal duty)
6.7 A at 480 V (normal duty)
6 A at 380 V (heavy duty)
5.4 A at 480 V (heavy duty)
prospective line Isc
50 kA
apparent power
5.6 kVA at 480 V (normal duty)
4.5 kVA at 480 V (heavy duty)
continuous output current
9.3 A at 4 kHz for normal duty
7.2 A at 4 kHz for heavy duty
maximum transient current
10.8 A during 60 s (heavy duty)
10.2 A during 60 s (normal duty)
asynchronous motor control profile
Variable torque standard
Constant torque standard
Optimized torque mode
synchronous motor control profile
Permanent magnet motor
Synchronous reluctance motor
Output frequency
0.0001…0.5 kHz
speed drive output frequency
0.1…599 Hz
nominal switching frequency
4 kHz
switching frequency
2…12 kHz adjustable
4…12 kHz with derating factor
safety function
STO (safe torque off) SIL 3
discrete input logic
16 preset speeds
communication port protocol
Ethernet
Modbus serial
Modbus TCP
option card
Slot A: communication module, Profibus DP V1
Slot A: communication module, Profinet
Slot A: communication module, DeviceNet
Slot A: communication module, Modbus TCP/EtherNet/IP
Slot A: communication module, CANopen daisy chain RJ45
Slot A: communication module, CANopen SUB-D 9
Slot A: communication module, CANopen screw terminals
Slot A/slot B: digital and analog I/O extension module
Slot A/slot B: output relay extension module
Slot A: communication module, Ethernet IP/Modbus TCP/MD-Link
Communication module, BACnet MS/TP
Communication module, Ethernet Powerlink
Complementary
output voltage
<= power supply voltage
permissible temporary current boost
1.1 x In during 60 s (normal duty)
1.5 x In during 60 s (heavy duty)
motor slip compensation
Not available in permanent magnet motor law
Adjustable
Automatic whatever the load
Can be suppressed
acceleration and deceleration ramps
Linear adjustable separately from 0.01…9999 s
braking to standstill
By DC injection
protection type
Thermal protection: motor
Safe torque off: motor
Motor phase break: motor
Thermal protection: drive
Safe torque off: drive
Overheating: drive
Overcurrent between output phases and earth: drive
Overload of output voltage: drive
Short-circuit protection: drive
Motor phase break: drive
Overvoltages on the DC bus: drive
Line supply overvoltage: drive
Line supply undervoltage: drive
Line supply phase loss: drive
Overspeed: drive
Break on the control circuit: drive
frequency resolution
Display unit: 0.1 Hz
Analog input: 0.012/50 Hz
electrical connection
Control: removable screw terminals0.5…1.5 mm²/AWG 20…AWG 16
Motor: screw terminal2.5…6 mm²/AWG 14…AWG 10
Line side: screw terminal2.5…6 mm²/AWG 14…AWG 10
connector type
RJ45 (on the remote graphic terminal) for Ethernet/Modbus TCP
RJ45 (on the remote graphic terminal) for Modbus serial
physical interface
2-wire RS 485 for Modbus serial
transmission frame
RTU for Modbus serial
transmission rate
10/100 Mbit/s for Ethernet IP/Modbus TCP
4.8, 9.6, 19.2, 38.4 kbit/s for Modbus serial
exchange mode
Half duplex, full duplex, autonegotiation Ethernet/Modbus TCP
data format
8 bits, configurable odd, even or no parity for Modbus serial
type of polarization
No impedance for Modbus serial
number of addresses
1…247 for Modbus serial
method of access
Slave Modbus TCP
supply
External supply for digital inputs: 24 V DC (19…30 V), <1.25 mA, protection type: overload and short-circuit protection
Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 mA, protection type: overload and short-circuit protection
Internal supply for digital inputs and STO: 24 V DC (21…27 V), <200 mA, protection type: overload and short-circuit protection
local signalling
3 LEDs for local diagnostic
3 LEDs (dual colour) for embedded communication status
4 LEDs (dual colour) for communication module status
1 LED (red) for presence of voltage
width
144 mm
height
350 mm
depth
203 mm
net weight
4.6 kg
analogue input number
3
analogue input type
AI1, AI2, AI3 software-configurable voltage: 0…10 V DC, impedance: 30 kOhm, resolution 12 bits
AI1, AI2, AI3 software-configurable current: 0…20 mA/4…20 mA, impedance: 250 Ohm, resolution 12 bits
discrete input number
8
discrete input type
DI1…DI6 programmable, 24 V DC (<= 30 V), impedance: 3.5 kOhm
DI5, DI6 programmable as pulse input: 0…30 kHz, 24 V DC (<= 30 V)
STOA, STOB safe torque off, 24 V DC (<= 30 V), impedance: > 2.2 kOhm
input compatibility
DI1…DI6: discrete input level 1 PLC conforming to EN/IEC 61131-2
DI5, DI6: discrete input level 1 PLC conforming to IEC 65A-68
STOA, STOB: discrete input level 1 PLC conforming to EN/IEC 61131-2
discrete input logic
Positive logic (source) (DI1…DI6), < 5 V (state 0), > 11 V (state 1)
Negative logic (sink) (DI1…DI6), > 16 V (state 0), < 10 V (state 1)
Positive logic (source) (DI5, DI6), < 0.6 V (state 0), > 2.5 V (state 1)
Positive logic (source) (STOA, STOB), < 5 V (state 0), > 11 V (state 1)
analogue output number
2
analogue output type
Software-configurable voltage AO1, AO2: 0…10 V DC impedance 470 Ohm, resolution 10 bits
Software-configurable current AO1, AO2: 0…20 mA, resolution 10 bits
sampling duration
2 ms +/- 0.5 ms (DI1…DI4) – discrete input
5 ms +/- 1 ms (DI5, DI6) – discrete input
5 ms +/- 0.1 ms (AI1, AI2, AI3) – analog input
10 ms +/- 1 ms (AO1) – analog output
accuracy
+/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input
+/- 1 % AO1, AO2 for a temperature variation 60 °C analog output
linearity error
AI1, AI2, AI3: +/- 0.15 % of maximum value for analog input
AO1, AO2: +/- 0.2 % for analog output
relay output number
3
relay output type
Configurable relay logic R1: fault relay NO/NC electrical durability 100000 cycles
Configurable relay logic R2: sequence relay NO electrical durability 100000 cycles
Configurable relay logic R3: sequence relay NO electrical durability 100000 cycles
refresh time
Relay output (R1, R2, R3): 5 ms (+/- 0.5 ms)
minimum switching current
Relay output R1, R2, R3: 5 mA at 24 V DC
maximum switching current
Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 250 V AC
Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 30 V DC
Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC
Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC
isolation
Between power and control terminals
Variable speed drive application selection
Compressor centrifugal Building – HVAC
Other application Food and beverage processing
Fan Mining mineral and metal
Pump Mining mineral and metal
Fan Oil and gas
Other application Water and waste water
Screw compressor Building – HVAC
Pump Food and beverage processing
Fan Food and beverage processing
Atomization Food and beverage processing
Electro submersible pump (ESP) Oil and gas
Water injection pump Oil and gas
Jet fuel pump Oil and gas
Compressor for refinery Oil and gas
Centrifuge pump Water and waste water
Positive displacement pump Water and waste water
Electro submersible pump (ESP) Water and waste water
Screw pump Water and waste water
Lobe compressor Water and waste water
Screw compressor Water and waste water
Compressor centrifugal Water and waste water
Fan Water and waste water
Conveyor Water and waste water
Mixer Water and waste water
Motor power range AC-3
4…6 kW at 380…440 V 3 phases
4…6 kW at 480…500 V 3 phases
mounting mode
Wall mount