Sale!

GV2ME20 Motor circuit breaker, TeSys GV2, 3P, 13-18 A, thermal magnetic, screw clamp terminals

28,851.00 7.5% VAT

Motor circuit breaker, TeSys GV2, 3P, 13-18 A, thermal magnetic, screw clamp terminals

 

SKU: GV2ME20 Category:

Product Overview

The GV2ME20 is a motor circuit breaker which operates in thermal magnetic trip unit technology. Its mounting positions are horizontal and vertical. It has an under voltage trip, shunt trip and control. The under voltage allows the motor circuit breaker to trip whenever there is voltage loss in the system. The shunt trip allows automatic control of tripping. The motor circuit breaker control can be locked in the NC position.

Main
range
TeSys
product name
TeSys GV2
device short name
GV2ME
device application
Motor
trip unit technology
Thermal-magnetic
Complementary
poles description
3P
network type
AC
utilisation category
AC-3 conforming to IEC 60947-4-1
Category A conforming to IEC 60947-2
network frequency
50/60 Hz conforming to IEC 60947-4-1
fixing mode
35 mm symmetrical DIN rail: clipped
Panel: screwed (with adaptor plate)
operating position
Any position
motor power kW
7.5 kW at 400/415 V AC 50/60 Hz
9 kW at 500 V AC 50/60 Hz
15 kW at 690 V AC 50/60 Hz
breaking capacity
100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
3 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
15 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
8 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
6 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service short-circuit breaking capacity
100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
75 % at 690 V AC 50/60 Hz conforming to IEC 60947-2
75 % at 500 V AC 50/60 Hz conforming to IEC 60947-2
50 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
50 % at 440 V AC 50/60 Hz conforming to IEC 60947-2
control type
Push-button
[In] rated current
18 A
thermal protection adjustment range
13…18 A
magnetic tripping current
223 A
[Ue] rated operational voltage
690 V AC 50/60 Hz conforming to IEC 60947-2
[Ui] rated insulation voltage
690 V AC 50/60 Hz conforming to IEC 60947-2
[Ith] conventional free air thermal current
18 A conforming to IEC 60947-4-1
[Uimp] rated impulse withstand voltage
IEC 60947-2 6 kV
power dissipation per pole
2.5 W
mechanical durability
100000 cycles
electrical durability
100000 cycles for AC-3 at 440 V
maximum operating rate
25 cyc/h
rated duty
Continuous conforming to IEC 60947-4-1
tightening torque
1.7 N.m on screw clamp terminals
suitability for isolation
Yes conforming to IEC 60947-1
phase failure sensitivity
Yes conforming to IEC 60947-4-1
height
89 mm
width
45 mm
depth
78.5 mm
net weight
0.26 kg

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.