Sale!

LV426317 Circuit breaker ComPact NSXm F (36 kA at 415 VAC), 4P 3d, 100 A rating TMD trip unit, EverLink connectors

61,620.00 7.5% VAT

Circuit breaker ComPact NSXm F (36 kA at 415 VAC), 4P 3d, 100 A rating TMD trip unit, EverLink connectors

 

Main
range
ComPact
product name
ComPact NSXm
range of product
ComPact NSXm
device short name
NSXm 100F
product or component type
Circuit breaker
device application
Protection
Distribution
Number of poles
4P
protected poles description
3d
neutral position
Left
[In] rated current
100 A at 40 °C
[Ue] rated operational voltage
690 V AC 50/60 Hz
network type
AC
network frequency
50/60 Hz
suitability for isolation
Yes conforming to EN/IEC 60947-2
utilisation category
Category A
[Icu] rated ultimate short-circuit breaking capacity
85 kA Icu at 220…240 V AC 50/60 Hz conforming to IEC 60947-2
36 kA Icu at 380…415 V AC 50/60 Hz conforming to IEC 60947-2
35 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
Performance level
F 36 kA 415 V AC
trip unit name
TM-D
trip unit technology
Thermal-magnetic
trip unit protection functions
LI
control type
Toggle
Circuit breaker mounting mode
By screws
Clip-on
Complementary
[Ui] rated insulation voltage
800 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage
8 kV
[Ics] rated service short-circuit breaking capacity
85 kA at 220…240 V AC 50/60 Hz conforming to IEC 60947-2
36 kA at 380…415 V AC 50/60 Hz conforming to IEC 60947-2
30 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2
mechanical durability
20000 cycles
electrical durability
10000 cycles at 440 V In
20000 cycles at 440 V In/2
5000 cycles at 690 V In
10000 cycles at 690 V In/2
mounting support
Plate
DIN rail
Connection terminals
1 Everlink lug wire size 2.5…95 mm², rigid or stranded aluminium/copper
1 Everlink lug wire size 2.5…70 mm², flexible copper
connection pitch
35 mm with spreaders
27 mm without spreaders
9 mm pitches
12 module
protection type
L : for overload protection (thermal)
I : for short-circuit protection (magnetic)
trip unit rating
100 A at 40 °C
Long-time pick-up adjustment type Ir (thermal protection)
Adjustable
[Ir] long-time protection pick-up adjustment range
0.7…1 x In
Long-time protection delay adjustment type tr
Fixed
[Im] magnetic protection pick-up range
1250 A
earth-leakage protection
Without
Number of slots for electrical auxiliaries
1 slot(s) for auxiliary switch OF
1 slot(s) for alarm switch SD
1 slot(s) for voltage release MN or MX