range of product |
Zelio Time
|
|
---|---|---|
product or component type |
Modular timing relay
|
|
discrete output type |
Relay
|
|
device short name |
RE22
|
|
nominal output current |
8 A
|
contacts type and composition |
1 C/O timed contact, cadmium free
|
|
---|---|---|
time delay type |
C
Ct |
|
time delay range |
10…100 s
3…30 s 0.05…1 s 30…300 s 30…300 h 30…300 min 3…30 min 3…30 h 0.3…3 s 1…10 s |
|
control type |
Rotary knob
Diagnostic button Potentiometer external |
|
[Us] rated supply voltage |
24…240 V AC/DC 50/60 Hz
|
|
Release input voltage |
<= 2.4 V
|
|
voltage range |
0.85…1.1 Us
|
|
supply frequency |
50…60 Hz +/- 5 %
|
|
connections – terminals |
Screw terminals, 1 x 0.5…1 x 3.3 mm² (AWG 20…AWG 12) solid without cable end
Screw terminals, 2 x 0.5…2 x 2.5 mm² (AWG 20…AWG 14) solid without cable end Screw terminals, 1 x 0.2…1 x 2.5 mm² (AWG 24…AWG 14) flexible with cable end Screw terminals, 2 x 0.2…2 x 1.5 mm² (AWG 24…AWG 16) flexible with cable end |
|
tightening torque |
0.6…1 N.m conforming to IEC 60947-1
|
|
housing material |
Self-extinguishing
|
|
repeat accuracy |
+/- 0.5 % conforming to IEC 61812-1
|
|
temperature drift |
+/- 0.05 %/°C
|
|
voltage drift |
+/- 0.2 %/V
|
|
setting accuracy of time delay |
+/- 10 % of full scale at 25 °C conforming to IEC 61812-1
|
|
Control signal pulse width |
100 ms with load in parallel
30 ms |
|
insulation resistance |
100 MOhm at 500 V DC conforming to IEC 60664-1
|
|
Recovery time |
120 ms on de-energisation
|
|
immunity to microbreaks |
10 ms
|
|
power consumption in VA |
3 VA at 240 V AC
|
|
power consumption in W |
1.5 W at 240 V DC
|
|
switching capacity in VA |
2000 VA
|
|
minimum switching current |
10 mA at 5 V DC
|
|
maximum switching current |
8 A
|
|
maximum switching voltage |
250 V AC
|
|
electrical durability |
100000 cycles, 8 A at 250 V, AC-1
100000 cycles, 2 A at 24 V, DC-1 |
|
mechanical durability |
10000000 cycles
|
|
Rated impulse withstand voltage |
5 kV for 1.2…50 µs conforming to IEC 60664-1
|
|
Power on delay |
100 ms
|
|
creepage distance |
4 kV/3 conforming to IEC 60664-1
|
|
overvoltage category |
III conforming to IEC 60664-1
|
|
safety reliability data |
MTTFd = 205.4 years
B10d = 190000 |
|
mounting position |
Any position
|
|
mounting support |
35 mm DIN rail conforming to EN/IEC 60715
|
|
status LED |
LED backlight green (steady) for dial pointer indication
LED yellow (steady) for output relay energised LED yellow (fast flashing) for timing in progress and output relay de-energised LED yellow (slow flashing) for timing in progress and output relay energised |
|
width |
22.5 mm
|
|
net weight |
0.1 kg
|
Reviews