range of product |
Harmony XB5
|
|
---|---|---|
product or component type |
Push-button
|
|
device short name |
XB5
|
|
bezel material |
Plastic
Dark grey plastic |
|
head type |
Standard
|
|
fixing collar material |
Plastic
|
|
mounting diameter |
0.87 in (22 mm)
|
|
sale per indivisible quantity |
1
|
|
shape of signaling unit head |
Round
|
|
type of operator |
spring return
|
|
operator profile |
Green flush, unmarked
|
|
contacts type and composition |
1 NO + 1 NC
|
|
contact operation |
Slow-break
|
|
connections – terminals |
Screw clamp terminals, <= 2 x 1.5 mm² with cable end conforming to EN/IEC 60947-1
Screw clamp terminals, 1 x 0.22…2 x 2.5 mm² without cable end conforming to EN/IEC 60947-1 |
height |
1.65 in (42 mm)
|
|
---|---|---|
width |
1.18 in (30 mm)
|
|
depth |
2.05 in (52 mm)
|
|
terminals description ISO n°1 |
(13-14)NO
(21-22)NC |
|
resistance to high pressure washer |
1015.26 psi (7000000 Pa) 131 °F (55 °C) 0.1 m
|
|
contacts usage |
Standard contacts
|
|
positive opening |
With EN/IEC 60947-5-1 appendix K
|
|
operating travel |
0.06 in (1.5 mm) NC changing electrical state)
0.10 in (2.6 mm) NO changing electrical state) 0.17 in (4.3 mm) total travel) |
|
operating force |
3.5 N NC changing electrical state
3.8 N NO changing electrical state |
|
mechanical durability |
10000000 cycles
|
|
tightening torque |
7.08…10.62 lbf.in (0.8…1.2 N.m) EN 60947-1
|
|
shape of screw head |
Cross Philips no 1
Cross pozidriv No 1 Slotted flat Ø 4 mm Slotted flat Ø 5.5 mm |
|
contacts material |
Silver alloy (Ag/Ni)
|
|
short-circuit protection |
10 A cartridge fuse gG EN/IEC 60947-5-1
|
|
[Ith] conventional free air thermal current |
10 A EN/IEC 60947-5-1
|
|
[Ui] rated insulation voltage |
600 V (pollution degree 3) conforming to EN/IEC 60947-1
|
|
[Uimp] rated impulse withstand voltage |
6 kV EN/IEC 60947-1
|
|
[Ie] rated operational current |
3 A 240 V, AC-15, A600 EN/IEC 60947-5-1
6 A 120 V, AC-15, A600 EN/IEC 60947-5-1 0.1 A 600 V, DC-13, Q600 EN/IEC 60947-5-1 0.27 A 250 V, DC-13, Q600 EN/IEC 60947-5-1 0.55 A 125 V, DC-13, Q600 EN/IEC 60947-5-1 1.2 A 600 V, AC-15, A600 EN/IEC 60947-5-1 |
|
electrical durability |
1000000 cycles AC-15, 2 A at 230 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1: appendix C
1000000 cycles AC-15, 3 A at 120 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1: appendix C 1000000 cycles AC-15, 4 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1: appendix C 1000000 cycles DC-13, 0.2 A at 110 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1: appendix C 1000000 cycles DC-13, 0.5 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1: appendix C |
|
electrical reliability |
Λ < 10exp(-6) 5 V 1 mA in clean environment EN/IEC 60947-5-4
Λ < 10exp(-8) 17 V 5 mA in clean environment EN/IEC 60947-5-4 |
|
device presentation |
Complete product
|
|
customizable |
Yes
|
|
customizable |
1
|
|
GCR BRIDGE |
XB5AACUST04
|
|
compatibility code |
XB5
|
Reviews