Sale!

1SBL921074R8010 AX18-30-10-80 220-230V50Hz/230-240V60Hz Contactor

8,715.00 7.5% VAT

AX18-30-10-80 220-230V50Hz/230-240V60Hz Contactor

SKU: 1SBL921074R8010 Category:

General Information

  • Extended Product Type:
    AX18-30-10-80
  • Product ID:
    1SBL921074R8010
  • EAN:
    3471522395801
  • Catalog Description:
    AX18-30-10-80 220-230V50Hz/230-240V60Hz Contactor
  • Long Description:
    AX09…AX25 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC. These contactors are of the block type design with: – 3 main poles and 1 built-in auxiliary contact – control circuit: AC operated – add-on auxiliary contact blocks for front or side mounting and a wide range of accessories.

Categories

  • Products » Low Voltage Products and Systems » Control Products » Contactors » Block Contactors

Technical

  • Number of Main Contacts NO:
    3
  • Number of Main Contacts NC:
    0
  • Number of Auxiliary Contacts NO:
    1
  • Number of Auxiliary Contacts NC:
    0
  • Rated Operational Voltage:
    Auxiliary Circuit 690 V
    Main Circuit 690 V
  • Rated Frequency (f):
    Auxiliary Circuit 50 / 60 Hz
    Main Circuit 50 / 60 Hz
  • Conventional Free-air Thermal Current (Ith):
    acc. to IEC 60947-4-1, Open Contactors q = 40 °C 28 A
    acc. to IEC 60947-5-1, q = 40 °C 16 A
  • Rated Operational Current AC-1 (Ie):
    (690 V) 40 °C 27 A
    (690 V) 70 °C 20 A
    (220 / 240 V) 55 °C 25 A
  • Rated Operational Current AC-3 (Ie):
    (220 / 230 / 240 V) 55 °C 18 A
    (380 / 400 V) 55 °C 18 A
    (415 V) 55 °C 18 A
    (440 V) 55 °C 12 A
    (500 V) 55 °C 12 A
    (690 V) 55 °C 9 A
  • Rated Operational Power AC-3 (Pe):
    (220 / 230 / 240 V) 4 kW
    (380 / 400 V) 7.5 kW
    (415 V) 9 kW
    (440 V) 5.5 kW
    (500 V) 7.5 kW
    (690 V) 7.5 kW
  • Rated Operational Current AC-15 (Ie):
    (220 / 240 V) 4 A
    (24 / 127 V) 6 A
    (400 / 440 V) 2 A
    (500 V) 2 A
    (690 V) 2 A
    (380 / 440 V) 3 A
  • Rated Short-time Withstand Current (Icw):
    at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 145 A
    at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 28 A
    at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 60 A
    at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 300 A
    at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 80 A
    for 0.1 s 140 A
    for 1 s 100 A
  • Maximum Breaking Capacity:
    cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 250 A
    cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 90 A
  • Maximum Electrical Switching Frequency:
    (AC-1) 600 cycles per hour
    (AC-15) 1200 cycles per hour
    (AC-3) 1200 cycles per hour
    (DC-13) 900 cycles per hour
  • Rated Operational Current DC-13 (Ie):
    (110 V) 1.1 A / 121 W
    (220 V) 0.55 A / 121 W
    (400 V) 2.8 A / 134 W
    (500 V) 2 A / 144 W
    (125 V) 1.1 A / 138 W
    (24 V) 6 A / 144 W
    (250 V) 0.55 A / 138 W
  • Rated Insulation Voltage (Ui):
    acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
  • Rated Impulse Withstand Voltage (Uimp):
    6 kV
  • Maximum Mechanical Switching Frequency:
    3600 cycles per hour
  • Rated Control Circuit Voltage (Uc):
    50 Hz 220 … 230 V
    60 Hz 230 … 240 V
  • Operate Time:
    Between Coil De-energization and NC Contact Closing 9 … 16 ms
    Between Coil De-energization and NO Contact Opening 4 … 11 ms
    Between Coil Energization and NC Contact Opening 7 … 21 ms
    Between Coil Energization and NO Contact Closing 10 … 26 ms
  • Degree of Protection:
    acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20
    acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
    acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
  • Terminal Type:
    Screw Terminals

Technical UL/CSA

  • General Use Rating UL/CSA:
    (600 V AC) 30 A
  • Horsepower Rating UL/CSA:
    (120 V AC) Single Phase 1 Hp
    (240 V AC) Single Phase 3 Hp
    (200 … 208 V AC) Three Phase 5 Hp
    (220 … 240 V AC) Three Phase 5 Hp
    (440 … 480 V AC) Three Phase 10 Hp
    (550 … 600 V AC) Three Phase 15 Hp
  • Tightening Torque UL/CSA:
    Auxiliary Circuit 9 in·lb
    Control Circuit 9 in·lb
    Main Circuit 9 in·lb

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.